Tärkeimmät tekniset tiedot
-
Process temperature
0 to 60 °C (32 to 140 °F)
Käyttöalue
The Flexdip CYA112 is a modular assembly for sensor immersion in open basins, channels, or tanks. It allows nearly any kind of sensor mounting – chain, fixed, or free-swinging – and features a quick fastener for rapid and safe installation of Memosens or fixed-cable sensors. The assembly provides you with outstanding flexibility and enables you to optimally configure your measurement at low costs.
Flexdip CYA112 is a modular assembly for all measurements in open basins, channels and tanks in:
Wastewater treatment plants
Water works
Utilities of all industries
It forms a perfect team with the Flexdip CYH112 holder for simple sensor isolation.
The Flexdip team is suitable for all parameters, such as:
pH/ORP
Conductivity
Oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
Edut
The modular system allows an optimum configuration for every measuring place
Fast installation and exchange of Memosens sensors with contactless plug-in head
Twist-free installation of fixed-cable sensors
Easy to install and to maintain
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
| FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
|---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
Edeltäjä
-
Mittausperiaate
Potentiometric
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Mittausperiaate
Sensor ORP / Redox
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Mittausperiaate
Conductive
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
Länge: 600, 1200, 1800 und 2400 mm
(23.6, 47.2, 70.9 und 94.5 Zoll) -
Process temperature
0 ... 60 °C (32 ... 140 °F)
-
Mittausperiaate
Amperometric oxygen measurement
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Mittausperiaate
Total chlorine
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Mittausperiaate
Single beam scattered light
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Mittausperiaate
UV photometric
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Process temperature
0 to 60 °C (32 to 140 °F)
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
-
Tekniset tiedot (TI)
Flexdip CYA112
-
Tekniset tiedot (TI)
Englanti - 12/2019New version available in EnglishImmersion assembly for water and wastewater
EN FI 13/12/201929/05/201201/05/2009Kieli:
Englanti
Versio:
13/12/2019
Tiedoston koko:
708.9 KB
Tiedoston nimi:
TI00432CEN_1419.pdf
-
-
-
Käyttöohje (BA)
Flexdip CYA112
-
Käyttöohje (BA)
Suomi - 12/2019New version available in EnglishJätevesikokoonpano
EN FI 13/12/201921/08/201301/05/2009Kieli:
Suomi
Versio:
13/12/2019
Tiedoston koko:
954.1 KB
Tiedoston nimi:
BA00432CFI_1419.pdf
-
-
-
Asennusohjeet (EA)
Kit manual for sample preparation systems CAT8xx Filter
-
Asennusohjeet (EA)
Englanti - 01/2026New version available in EnglishKit manual for sample preparation systems CAT8xx Filter - two-sided
EN FI 16/01/2026Kieli:
Englanti
Versio:
16/01/2026
Tiedoston koko:
2.1 MB
Tiedoston nimi:
71223012 Anleitung Kits CAT8xx Filter 2020-06.pdf
-
-
-
Toiminta-alueet (FA)
Sensors, transmitters, compact devices and assemblies
-
Toiminta-alueet (FA)
Englanti - 02/2026New version available in EnglishExperts in Liquid Analysis
Kieli:
Englanti
Versio:
02/02/2026
Tiedoston koko:
4.2 MB
Tiedoston nimi:
FA00007C_EN_Analyse_22-26_LowRes.pdf
-
-
-
Toiminta-alueet (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
-
Toiminta-alueet (FA)
Saksa - 02/2026New version available in EnglishKompetenz in der Flüssigkeitsanalyse
Kieli:
Saksa
Versio:
02/02/2026
Tiedoston koko:
4.3 MB
Tiedoston nimi:
FA00007C_DE_Analyse_22-26_LowRes.pdf
-
-
-
Toiminta-alueet (FA)
Endress+Hauser 水質分析計ファミリ
-
Toiminta-alueet (FA)
Japani - 03/2017New version available in Englishラインナップと事例
Kieli:
Japani
Versio:
23/03/2017
Tiedoston koko:
34.8 MB
Tiedoston nimi:
FA00007CJA_2022_Endress Hauser liquid analysis family.pdf
-
-
-
Esite (CP)
pH-Messung in Industrieprozessen
-
Esite (CP)
Saksa - 12/2021New version available in EnglishAuswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenKieli:
Saksa
Versio:
01/12/2021
Tiedoston koko:
3.3 MB
Tiedoston nimi:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
-
-
-
Esite (CP)
産業プロセスにおける導電率の測定
-
Esite (CP)
Japani - 01/2024New version available in Englishさまざまな産業およびアプリケーション向けの選択およびエンジニアリングガイド
Kieli:
Japani
Versio:
12/01/2024
Tiedoston koko:
3.5 MB
Tiedoston nimi:
CP01313CJA_0223_1024_Conductivity_sensor_selection_guide.pdf
-
-
-
Esite (CP)
pH measurement in industrial processes
-
Esite (CP)
Englanti - 12/2021New version available in EnglishSelection and engineering guide for different industries and
applicationsKieli:
Englanti
Versio:
02/12/2021
Tiedoston koko:
3.2 MB
Tiedoston nimi:
CP00010CEN_1621_pH selection guide_2021.pdf
-
-
-
Esite (CP)
産業プロセスにおけるpH測定
-
Esite (CP)
Japani - 02/2024New version available in Englishさまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Kieli:
Japani
Versio:
08/02/2024
Tiedoston koko:
2.6 MB
Tiedoston nimi:
CP00010CJA_1315_1024_pH_selection_guide.pdf
-
Tee valinta ehdotetuista vaihtoehdoista
-
-- selected coding-- selected label99.999,00<%label%>
-
Etsitkö lisää vaihtoehtoja? Jatka eteenpäin yksilöllisellä konfiguraattorilla .
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Etsitkö lisää vaihtoehtoja? Jatka eteenpäin yksilöllisellä konfiguraattorilla .
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-piirustukset CAD-piirustukset
- CAD-piirustukset
-
Hinnat per kpl.
-
<%range%><%price%>
-
- Valinnaiset lisäosat
Yksilöllinen konfiguraattori
Ostettu usein yhdessä
Lisätarvikkeet
Tähän liittyvät tuotteet