Proline Promass H 300 for the chemical industry
Tärkeimmät tekniset tiedot
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Käyttöalue
The highly accurate Promass H is destined for applications requiring maximum corrosion resistance and guarantees optimal safety for chemically aggressive fluids. With its compact transmitter Promass H 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables process safety at all times.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance
Device properties
Measuring tube made of Tantalum, Zirconium
Nominal diameter: DN 8 to 50 (3/8 to 2")
Medium temperature up to +205 °C (+401 °F)
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Edut
Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in-/outlet run needs
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videot
-
The Coriolis Flow Measuring Principle
Edeltäjä
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
| FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
|---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
-
Mittausperiaate
Coriolis
-
Product headline
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter.
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. -
Sensor features
Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) -
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Mittausperiaate
Coriolis
-
Product headline
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter.
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. -
Sensor features
Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) -
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Mittausperiaate
Coriolis
-
Product Headline
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter.
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. -
Sensor features
Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
-
Mittausperiaate
Coriolis
-
Product headline
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter.
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. -
Sensor features
Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 8 to 50 (³⁄₈ to 2")
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) -
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) -
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
-
Tekniset tiedot (TI)
TI Proline Promass H 300
-
Tekniset tiedot (TI)
Englanti - 11/2025New version available in EnglishCoriolis flowmeter
EN FI 11/11/202501/08/202216/09/201915/07/201901/11/2018Kieli:
Englanti
Versio:
11/11/2025
Tiedoston koko:
8.9 MB
Tiedoston nimi:
TI01273DEN_0825-00.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300 EtherNet/IP Operating Instructions
-
Käyttöohje (BA)
Englanti - 10/2017New version available in EnglishCoriolis flowmeter
EN FI 02/10/2017Kieli:
Englanti
Versio:
02/10/2017
Tiedoston koko:
7.6 MB
Tiedoston nimi:
BA01729DEN_0117.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300 PROFIBUS DP Operating Instructions
-
Käyttöohje (BA)
Englanti - 06/2018New version available in EnglishCoriolis flowmeter
EN FI 01/06/2018Kieli:
Englanti
Versio:
01/06/2018
Tiedoston koko:
6.8 MB
Tiedoston nimi:
BA01858DEN_0118.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300
-
Käyttöohje (BA)
Englanti - 08/2022New version available in EnglishCoriolis flowmeter
Modbus RS485EN FI 01/08/202201/09/201902/10/201701/08/2016Kieli:
Englanti
Versio:
01/08/2022
Tiedoston koko:
7.5 MB
Tiedoston nimi:
BA01497DEN_0422-00.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300 PROFINET Operating Instructions
-
Käyttöohje (BA)
Englanti - 09/2019New version available in EnglishCoriolis flowmeter
EN FI 16/09/201915/07/201902/10/2017Kieli:
Englanti
Versio:
16/09/2019
Tiedoston koko:
9.8 MB
Tiedoston nimi:
BA01740DEN_0319.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300 FOUNDATION Fieldbus Operating Instructions
-
Käyttöohje (BA)
Englanti - 11/2016New version available in EnglishCoriolis flowmeter
EN FI 01/11/2016Kieli:
Englanti
Versio:
01/11/2016
Tiedoston koko:
6.8 MB
Tiedoston nimi:
BA01519DEN_0116.pdf
-
-
-
Käyttöohje (BA)
BA Proline Promass H 300
-
Käyttöohje (BA)
Englanti - 01/2024New version available in EnglishCoriolis flowmeter
PROFINET with Ethernet-APLEN FI 08/01/2024Kieli:
Englanti
Versio:
08/01/2024
Tiedoston koko:
7.5 MB
Tiedoston nimi:
BA02111DEN_0122-00.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300 PROFIBUS PA Operating Instructions
-
Käyttöohje (BA)
Englanti - 11/2018New version available in EnglishCoriolis flowmeter
EN FI 01/11/201801/08/2016Kieli:
Englanti
Versio:
01/11/2018
Tiedoston koko:
6.7 MB
Tiedoston nimi:
BA01508DEN_0218.pdf
-
-
-
Käyttöohje (BA)
Proline Promass H 300
-
Käyttöohje (BA)
Englanti - 08/2022New version available in EnglishCoriolis flowmeter
HARTEN FI 01/08/202201/09/201902/10/201701/08/2016Kieli:
Englanti
Versio:
01/08/2022
Tiedoston koko:
8.5 MB
Tiedoston nimi:
BA01486DEN_0422-00.pdf
-
-
-
Käyttöohje (BA)
BA Proline Promass H 300
-
Käyttöohje (BA)
Englanti - 11/2025New version available in EnglishCoriolis flowmeter
Modbus TCPEN FI 11/11/2025Kieli:
Englanti
Versio:
11/11/2025
Tiedoston koko:
7.1 MB
Tiedoston nimi:
BA02405DEN_0125-00.pdf
-
Tee valinta ehdotetuista vaihtoehdoista
-
-- selected coding-- selected label99.999,00<%label%>
-
Etsitkö lisää vaihtoehtoja? Jatka eteenpäin yksilöllisellä konfiguraattorilla .
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Etsitkö lisää vaihtoehtoja? Jatka eteenpäin yksilöllisellä konfiguraattorilla .
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-piirustukset CAD-piirustukset
- CAD-piirustukset
-
Hinnat per kpl.
-
<%range%><%price%>
-
- Valinnaiset lisäosat
Yksilöllinen konfiguraattori
Ostettu usein yhdessä
Lisätarvikkeet
Tähän liittyvät tuotteet