Deltabar S PMD70

Tuotekuva: Deltabar S PMD70

Tämä tuote ei enää ole saatavilla.

Tutustu uuteen sukupolveen edeltäjän / seuraavan mallin osiossa tai ota yhteyttä paikalliseen Endress+Hauser -edustajaan.

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Differential pressure

  • Product headline

    Digital transmitter with ceramic measuring diaphragms
    Modular transmitter
    Long-term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 150bar
    (max. 2.172 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX
    FM
    CSA
    NEPSI
    IECEx
    SIL
    Schiffbau GL
    WHG/ Überfüllsicherung
    EN 10204-3.1

  • Mittausperiaate

    Differential pressure

  • Characteristic / Application

    Digital transmitter with ceramic measuring diaphragms
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply / Communication

    4...20 mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,075%
    "PLATINUM" 0,05%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -20°C...85°C
    (-4°F...185°F)

  • Process temperature

    -20°C...85°C
    (-4°F...185°F)

  • Process pressure absolute / max. overpressure limit

    150 bar (2250psi)

  • Pressure measuring range

    25mbar...3 bar
    (0.36psi...45psi)

  • Main wetted parts

    Ceramic
    Alloy C276
    316L
    Monel
    Tantalum

  • Process connection

    1/4-18NPT
    RC1/4"

  • Max. measurement distance

    30m (98ft)H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    NEPSI
    IECEx
    SIL
    GL marine
    WHG/ Overfill prevention
    EN10204-3.1

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Successor

    PMD75

  • Application limits

    Measuring cell:

    Ceramic

  • Mittausperiaate

    Differential pressure

  • Product headline

    Digital transmitter with ceramic measuring diaphragms
    Modular transmitter
    Long-term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 150bar
    (max. 2.175 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX
    FM
    CSA
    NEPSI
    IECEx
    SIL
    Schiffbau GL
    WHG/ Überfüllsicherung
    EN 10204-3.1

  • Mittausperiaate

    Differential pressure

  • Characteristic

    Digital transmitter with ceramic measuring diapragms
    Modular transmitter
    Long-term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply voltage

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Reference Accuracy

    0,075%
    "PLATINUM" 0,05%

  • Long term stability

    0,05% of URL/year
    0,125% of URL/5 years

  • Process temperature

    -20°C...85°C
    (-4°F...185°F)

  • Ambient temperature

    -20°C...85°C
    (-4°F...185°F)

  • Measuring cell

    25mbar...3bar
    (10inH2O...45psi)

  • Max. overpressure limit

    on one side:

    100 bar

    (1500 psi)

  • Process connection

    1/4-18NPT
    RC1/4"

  • Communication

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    NEPSI
    IECEx

  • Safety approvals

    SIL
    Overfill prevention WHG

  • Design approvals

    EN10204-3.1

  • Marine approvals

    GL

  • Specialities

    diagnostic functions

  • Successor

    PMD75

  • Mittausperiaate

    Differential pressure

  • Product headline

    Digital transmitter with ceramic measuring diaphragms
    Modular transmitter
    Long-term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Max. measurement error

    0,075%
    "PLATINUM" 0,05%

  • Max. process pressure

    max. 150bar
    (max. 2.172 psi)

  • Medium temperature range

    Temperature gradient from pressure piping

  • Display/Operation

    Option

  • Outputs

    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Digital communication

    HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX
    FM
    CSA
    NEPSI
    IECEx
    SIL
    Schiffbau GL
    WHG/ Überfüllsicherung
    EN 10204-3.1

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely
  • 12
    • Nro 12 Tilauskoodi 52020440

      Mounting set housing T14/T15 / sensor

      Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 12 Tilauskoodi 71020596

      Mounting set housing T17 / sensor

      Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 13
    • Nro 13 Tilauskoodi 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 13 Tilauskoodi 52022419

      Push button housing, HART, version 1

      Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 13 Tilauskoodi 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

    • Tilauskoodi 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Tilauskoodi 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 15
  • 21
  • 20
    • Nro 20 Tilauskoodi 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 20 Tilauskoodi 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 20 Tilauskoodi 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 20 Tilauskoodi 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nro 20 Tilauskoodi 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nro 20 Tilauskoodi 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

    • Nro 20 Tilauskoodi 71245249

      Cover T14/T15 Alu,Exd,sight glass,gasket

      Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 20 Tilauskoodi 71245250

      Cover T14 316L, Ex d, sight glass, EPDM

      Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Tilauskoodi 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Tilauskoodi 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Tilauskoodi 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Tilauskoodi 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Tilauskoodi 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 25
  • 20
    • Nro 20 Tilauskoodi 71206968

      Cover T14 316L, Ex d, sight glass, FVMQ

      Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nro 30 Tilauskoodi 52024111

      Electronics HART Ex, ext. p. b., v2.0

      4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 52024400

      Electronics HART Ex, v2.0

      4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nro 30 Tilauskoodi 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nro 30 Tilauskoodi 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71214057

      Electronics PA, Ex, HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71214064

      Electronics PA, ext. p.b.,HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71214066

      Electronics FF, ext. p.b.,HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71214069

      Electronics FF, HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nro 30 Tilauskoodi 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nro 30 Tilauskoodi 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nro 30 Tilauskoodi 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 31
  • 35
  • 40
    • Nro 40 Tilauskoodi 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

  • 55
  • 57
  • 50
  • 65
  • Seuraava malli