Specs at a glance
-
Measuring range
0 to 500 µg/l (ppb)
50 to 5000 µg/l (ppb) -
Process temperature
5 to 45 °C (41 to 113 °F)
-
Process pressure
1 to 5 bar (14.5 to 72.5 psi)
-
Measuring method
Comply with standard colorimetric measuring principle - heteropoly blue method
Field of application
Liquiline System CA80SI provides precise online analysis of silica and helps protect plant equipment from glass-like deposits ensuring optimum performance of turbines and ion exchangers. Its unique combination of peristaltic and high-precision dispenser pumps enables extremely reliable operation and low maintenance. The silica analyzer offers advanced diagnostics and can be easily adapted to your process needs by retrofitting up to 6 channels and connecting up to 4 Memosens sensors.
The CA80SI silica analyzer monitors trace levels of silica in the power industry and utilities:
Indication of the purity of boiler feed water and steam
Provision of early warning for condenser leaks
Early warning of exhaustion of ion exchangers
Benefits
Early online detection of critical silica levels ensures efficient power plant performance and optimizes maintenance and blowdown cycles by early counter measures.
Standard heteropoly blue method allows direct comparability to lab results.
-
Best reliability: Unique combination of peristaltic and high-precisions dispenser pumps ensures stable operation and low maintenance.
Optimized investment: The option of up to 6 sample channels meets changing process needs at any time, and connection of Memosens sensors allows an easy upgrade to a complete measuring station.
Seamless integration into process control systems thanks to digital field buses such as Modbus, EtherNet/IP or PROFIBUS.
Advanced diagnostics and remote access via web server enable fast remedy in case of errors.
Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.
Videos
-
Silica concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for silica in aqueous solutions
-
Measuring method
Comply with standard colorimetric measuring principle - heteropoly blue method
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design / cabinet
Plastic ASA-PC -
Process temperature
5 to 45 °C (41 to 113 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
-
Process pressure
1 to 5 bar (14.5 to 72.5 psi)
-
Sample flow rate
60 to 250 ml/min (2.03 to 8.45 fl.oz/min)
-
Consistency of the sample
Particle free
-
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
optional up to 6 sample channels
Flexible functionality and modular expandable
Digital communication for remote access -
Application
Determination of silica concentration in boiler feed water
Monitoring of water-steam-circuit and condensate
Monitoring and optimization of reverse osmosis and desalination -
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
50 ± 1 or 60 ± 1.2 Hz -
Output / communication
2x 0/4 to 20 mA
Optional: Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1, 2, 4 or 6 measuring channels
Optional 1 to 4 digital inputs for sensors with Memosens protocol -
Measuring range
0 to 500 µg/l (ppb)
50 to 5000 µg/l (ppb) -
Consumables
Reagents and standard solutions CY80SI
Maintenance kit CAV800
-
-
Technical Information (TI)
TI Liquiline System CA80SI
-
Technical Information (TI)
English version - 02/2025New version available in EnglishColorimetric analyzer for silica
EN 28/02/202523/05/202430/11/202231/03/202231/05/2021Language:
English
Version:
28/02/2025
File size:
4.3 MB
File name:
TI01315CEN_0725-00.pdf
-
-
-
Operating Instruction (BA)
BA Liquiline System CA80SI
-
Operating Instruction (BA)
English version - 03/2025New version available in EnglishColorimetric analyzer for silica
EN 03/03/202523/05/202430/11/202231/03/202231/05/2021Language:
English
Version:
03/03/2025
File size:
6.2 MB
File name:
BA01650CEN_0725-00.pdf
-
-
-
Operating Instruction (BA)
Memosens
-
Operating Instruction (BA)
English version - 05/2022New version available in EnglishSensor inputs with Memosens protocol
EN 30/05/202228/02/2019Language:
English
Version:
30/05/2022
File size:
3.3 MB
File name:
BA01245CEN_0822-00.pdf
-
-
-
Short Instruction (KA)
Liquiline System CA80SI
-
Short Instruction (KA)
English version - 05/2021New version available in EnglishColorimetric analyzer for silica
EN 31/05/202116/12/201921/11/2018Language:
English
Version:
31/05/2021
File size:
3 MB
File name:
KA01281CEN_0321.pdf
-
-
-
Installation Instructions (EA)
EA Liquiline System CA80SI/82HA analyzer
-
Installation Instructions (EA)
English version - 06/2025New version available in EnglishProcess engineering
EN 23/06/2025Language:
English
Version:
23/06/2025
File size:
2.6 MB
File name:
EA01681CEN_0125-00.pdf
-
-
-
Installation Instructions (EA)
Kit CM44x/CSXxx/CA80XX
-
Installation Instructions (EA)
English version - 11/2022New version available in EnglishModule 485MB or 485DP
For Ethernet configuration, PROFIBUS DP, Modbus RS485EN 28/11/2022Language:
English
Version:
28/11/2022
File size:
1.8 MB
File name:
EA01447CEN_0122-00.pdf
-
-
-
Installation Instructions (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
-
Installation Instructions (EA)
English version - 07/2014New version available in EnglishFür erweiterte Funktionalität
For extended functionalityEN 07/07/201425/03/201331/12/2011Language:
English
Version:
07/07/2014
File size:
2.4 MB
File name:
EA00008CA2_0314.pdf
-
-
-
Installation Instructions (EA)
EA Liquiline System analyzer CA80COD/TP
-
Installation Instructions (EA)
English version - 10/2025New version available in EnglishWear parts
EN 31/10/2025Language:
English
Version:
31/10/2025
File size:
3.1 MB
File name:
EA01718CEN_0125-00.pdf
-
-
-
Installation Instructions (EA)
Kits for Analyzer CA80: Engineering parts
-
Installation Instructions (EA)
English version - 06/2025New version available in EnglishKits for Analyzer CA80: Engineering parts
EN 30/06/2025Language:
English
Version:
30/06/2025
File size:
2.1 MB
File name:
71223028 Anleitung Kits CA8x Verfahrenstechnik 2022-08.pdf
-
-
-
Installation Instructions (EA)
EA Kit for CA80SI Photometer
-
Installation Instructions (EA)
English version - 02/2025New version available in EnglishSpare part kits for silica analyzer CA80SI photometer
EN 12/02/2025Language:
English
Version:
12/02/2025
File size:
833.5 KB
File name:
71408598 Anleitung Kits CA80SI Photometer 2025-01.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products