Tärkeimmät tekniset tiedot
-
Process temperature
–50°C...+150°C
(–58°F...+300°F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(580 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU)
Käyttöalue
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for liquids up to SIL3.
Process connections: Threads and flanges
Temperature: -50 to +150°C (-76 to +300°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Sensor length: Extension pipe up to 3m (9.8ft)
Sensor material: Enamel, ECTFE and various PFA materials
International explosion protection certificates, overfill protection WHG, SIL
Edut
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
Permanent self-monitoring/internal redundancy
4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
No adjustment: quick, low-cost startup
No mechanically moving parts: no maintenance, no wear, long operating life
Monitoring of fork for damage, corrosion, buildup and mechanical blocking
Videot
Xpert-valikoima
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
-
-
Tekniset tiedot (TI)
Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information
Vibronic
Point level switch for liquidsEN FI 04/06/201316/07/2012Kieli:
Englanti
Versio:
04/06/2013
Tiedoston koko:
678.4 KB
Tiedoston nimi:
TI01026FEN_0213.pdf
-
-
-
Käyttöohje (BA)
Liquiphant FailSafe FTL80, FTL81, FTL85 Operating Instructions
Vibronic
Point level switch for liquidsEN FI 04/06/201316/07/2012Kieli:
Englanti
Versio:
04/06/2013
Tiedoston koko:
768.4 KB
Tiedoston nimi:
BA01037FEN_0213.pdf
-
-
-
Asennusohjeet (EA)
Diagnostics plug Installation instruction
Liquiphant M/S/FailSafe, Soliphant T/M
EN FI 24/04/201511/10/2012Kieli:
Englanti
Versio:
24/04/2015
Tiedoston koko:
71.5 KB
Tiedoston nimi:
EA01063FA2_0215.pdf
-
-
-
Asennusohjeet (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN FI 24/02/202215/08/201409/08/2012Kieli:
Englanti
Versio:
24/02/2022
Tiedoston koko:
119 KB
Tiedoston nimi:
EA01050FA2_0322.pdf
-
-
-
Asennusohjeet (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN FI 11/08/201409/08/2012Kieli:
Englanti
Versio:
11/08/2014
Tiedoston koko:
164.3 KB
Tiedoston nimi:
EA01048FA2_0214.pdf
-
-
-
Asennusohjeet (EA)
Cover for housing F27 Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN FI 11/08/201416/01/201409/08/2012Kieli:
Englanti
Versio:
11/08/2014
Tiedoston koko:
136.4 KB
Tiedoston nimi:
EA01047FA2_0314.pdf
-
-
-
Asennusohjeet (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN FI 11/08/201409/08/2012Kieli:
Englanti
Versio:
11/08/2014
Tiedoston koko:
134.4 KB
Tiedoston nimi:
EA01046FA2_0214.pdf
-
-
-
Asennusohjeet (EA)
Graphite gaskets Installation instruction
Liquiphant M, LIquiphant S, Liquiphant FailSafe
EN FI 11/04/2012Kieli:
Englanti
Versio:
11/04/2012
Tiedoston koko:
363.6 KB
Tiedoston nimi:
EA0008FA2_0708.pdf
-
-
-
Asennusohjeet (EA)
Electronics on Liquiphant M/S/FailSafe Installation instruction
Liquiphant M/S/FailSafe
EN FI 09/07/2012Kieli:
Englanti
Versio:
09/07/2012
Tiedoston koko:
359 KB
Tiedoston nimi:
EA01030FA2_0112.pdf
-
-
-
Asennusohjeet (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN FI 09/08/2012Kieli:
Englanti
Versio:
09/08/2012
Tiedoston koko:
158.7 KB
Tiedoston nimi:
EA01049FA2_01.12.pdf
-
-
-
Asennusohjeet (EA)
Cover for Housing F17 Installation instruction
LIquiphant M/S/Fail Safe,Soliphant M
EN FI 11/08/201412/07/2012Kieli:
Englanti
Versio:
11/08/2014
Tiedoston koko:
144.8 KB
Tiedoston nimi:
EA01036FA2_0214.pdf
-
-
-
Asennusohjeet (EA)
Cover for Housing F16 Installation instruction
LIquiphant M/S/Fail Safe,Soliphant M
EN FI 12/07/2012Kieli:
Englanti
Versio:
12/07/2012
Tiedoston koko:
103.1 KB
Tiedoston nimi:
EA01035FA2_0112.pdf
-
-
-
Asennusohjeet (EA)
Cover for Housing F15 Installation instruction
LIquiphant M/S/Fail Safe,Soliphant M, Cerabar M, Deltapilot M
EN FI 11/08/201412/07/2012Kieli:
Englanti
Versio:
11/08/2014
Tiedoston koko:
142.9 KB
Tiedoston nimi:
EA01034FA2_0214.pdf
-
-
-
Ex-turvallisuusohje (XA)
Liquiphant FailSafe FTL80, FTL81, FTL85
II 1 G Ex ia IIC T6 Ga
II 1/2 G Ex ia IIC T6 Ga/GbKieli:
Englanti
Versio:
09/08/2021
Tiedoston koko:
441 KB
Tiedoston nimi:
XA02604FEN_0121-00.pdf
-
-
-
Ex-turvallisuusohje (XA)
Liquiphant FailSafe FTL80, FTL81, FTL85
II 1/2 G Ex db IIC T6 Ga/Gb
Kieli:
Englanti
Versio:
09/08/2021
Tiedoston koko:
443.3 KB
Tiedoston nimi:
XA02605FEN_0121-00.pdf
-
-
-
Ex-turvallisuusohje (XA)
Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing
IS + XPEN FI 06/06/201320/03/2013Kieli:
Englanti
Versio:
06/06/2013
Tiedoston koko:
259.5 KB
Tiedoston nimi:
XA00657FEN_0213.pdf
-
-
-
Ex-turvallisuusohje (XA)
Liquiphant FailSafe FTL80, FTL81, FTL85
ATEX:
II 1/2 G Ex db IIC T6 Ga/Gb
II 1/2 D Ex ta IIIC T80°C Da/Db
IECEx:
Ex db IIC T6 Ga/Gb
Ex ta IIIC T80°C Da / Ex tb IIIC T80°C DbEN FI 02/03/202005/04/201603/07/201301/07/2012Kieli:
Englanti
Versio:
02/03/2020
Tiedoston koko:
1.7 MB
Tiedoston nimi:
XA00653FA3_0419.pdf
-
-
-
Ex-turvallisuusohje (XA)
Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing
XP + NIKieli:
Englanti
Versio:
06/06/2013
Tiedoston koko:
201.6 KB
Tiedoston nimi:
XA00655FEN_0112.pdf
-
-
-
Ex-turvallisuusohje (XA)
Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing
NIKieli:
Englanti
Versio:
06/06/2013
Tiedoston koko:
191.8 KB
Tiedoston nimi:
XA00676FEN_0112.pdf
-
-
-
Ex-turvallisuusohje (XA)
Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
Control Drawing
XP + NIEN FI 03/07/201301/07/2012Kieli:
Englanti
Versio:
03/07/2013
Tiedoston koko:
157 KB
Tiedoston nimi:
XA00656FEN_0213.pdf
-