Starter 785 nm: 300-3300 cm-1 Base model 532 nm: 150-4350 cm-1 Base model 785 nm: 150-3425 cm-1 Base model 1000 nm: 200-2400 cm-1 Hybrid 785 nm: 175-1890 cm-1
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Learn how Raman Spectroscopy can provide analysis solutions for challenging stream conditions, by reading the white paper focused on two different customer case studies.
Starter 785 nm: 300-3300 cm-1 Base model 532 nm: 150-4350 cm-1 Base model 785 nm: 150-3425 cm-1 Base model 1000 nm: 200-2400 cm-1 Hybrid 785 nm: 175-1890 cm-1
Spectral resolution
Starter: 10 cm-1 (average) Base model (average): 5 cm-1 (532 nm) 4 cm-1 (785 nm) 6 cm-1 (1000 nm) Hybrid: 4 cm-1 (785 nm) average
Channels
Starter: Single channel Base Model: Up to four channels Hybrid: Up to two channels
Ambient temperature
Operating: 15 to 30 °C 59 to 86 °F Storage: -15 to 50 °C 5 to 122 °F
Starter 785 nm: 300-3300 cm-1 Base model 532 nm: 150-4350 cm-1 Base model 785 nm: 150-3425 cm-1 Base model 1000 nm: 200-2400 cm-1 Hybrid 785 nm: 175-1890 cm-1
Spectral resolution
Starter: 10 cm-1 (average) Base model (average): 5 cm-1 (532 nm) 4 cm-1 (785 nm) 6 cm-1 (1000 nm) Hybrid: 4 cm-1 (785 nm) average
Channels
Starter: Single channel Base Model: Up to four channels Hybrid: Up to two channels
Ambient temperature
Operating: 15 to 30 °C 59 to 86 °F Storage: -15 to 50 °C 5 to 122 °F
Bioprocessing infrastructure readiness for online analytical
instrumentation integration - Is your upstream operation ready for
seamless deployment of an online Raman spectroscopy system?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps pharmaceutical and API manufacturers evaluate their readiness for implementing online Raman spectroscopy. A simple scoring system identifies potential infrastructure, integration, and process monitoring challenges, helping teams assess deployment complexity and prepare for successful real-time analytical monitoring.
Analytical costs, scale-up delays, and optimization potential in
upstream bioprocessing - Is your upstream process costing more than
you think?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps bioprocessing teams evaluate analytical costs and delays associated with scaling up from laboratory development to production. A scoring system helps identify optimization opportunities and assess the value of real-time monitoring using online Raman spectroscopy.
Raman flow assembly - Precise composition measurement of
high-speed, low-volume samples in downstream bioprocessing
PU (julkaisu)
Englanti - 05/2023
New version available in English
An overview of the Raman flow assembly (flow bench and flow cell) used with the Rxn-10 probe in conjunction with a Raman Rxn2 analyzer and a Raman flow assembly calibration and verification kit for downstream bioprocessing (powered by Kaiser Raman technology).
Raman data library -- Faster time to market with
increased insight, productivity, and data integrity
PU (julkaisu)
Englanti - 06/2024
New version available in English
This document provides insight into the core and cGxP features of Raman data library (data organization, visualization, user management, and univariate analysis for Raman Rxn2 and Raman Rxn4 analyzers), while also addressing common questions regarding the software's functionalities.
Graphic illustrating the core elements of Biopharma 4.0 including product lifecycle stages, role of PAT/QbD, and 12 key advanced technologies for scientists and process engineers in the Life Sciences, applicable to Raman spectroscopy systems (Raman Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve, flow cell and flow bench, Raman optic system for single use, and Raman calibration & verification kits).
Prioritize scalability for an efficient biopharmaceutical
product development lifecycle
PU (julkaisu)
Tšekki - 09/2024
New version available in English
This technical paper studies the importance of scalability as a competitive advantage in bioprocessing in the Life Science industry, and Endress+Hauser's scalable Raman systems (Raman Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve, flow cell and flow bench, Raman optic system for single use) and liquid analysis sensor technology and Liquid Analysis portfolio (Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E, CLS82E).