Microwave barrier receiver
Soliwave FDR50

Soliwave FDR50 aluminum hosuing ©Endress+Hauser
Soliwave FDR50 stainless steel hosuing ©Endress+Hauser

Receiver for non-contact point level detection in bulk solids

The Soliwave FDR50 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR50 emitter.

  • Edut

    • Highly reliable measurement due to adjustable sensitivity and indication of the signal strength on the receiver

    • Mechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, long serviceable life,...

  • Käyttöalue

    Typical bulk solids are: Wood chips, wood dust or flour, plaster, cement, ash, paper or cardboard shred, gravel, sand, dried powders in general, bags and boxes.

    • Process connections: Threads

    • Ambient temperature: -20 to +70°C (-4 to +158°F)

    • Measuring...

Ominaisuudet ja tiedot

Takaisin

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Microwave barrier

  • Characteristic / Application

    Microwave receiver

  • Ambient temperature

    -20 °C ... 70 °C

    (-4 °F ... 158 °F)

  • Process temperature

    Waves emitted from outside (non-contact): any
    Waves emitted within installation (contact):

    -20°C...70°C
    (-4°F...158°F)

  • Process pressure absolute / max. overpressure limit

    Waves emitted from outside (contactless): any
    Waves emitted within installation (contact):
    0.8 bar abs ... 4,8 bar abs (12 psi ... 70 psi)

  • Min. density of medium

    Solid weight: >10 g/l

  • Main wetted parts

    Within installation: Aluminium, PTFE
    Or: non-contact

  • Process connection

    1-1/2" G + NPT
    With wave emission from outside / mounting from outside, metal container must not be made of metal

  • Process connection hygienic

    With waves emitted from outside (non-contact)

  • Communication

    Transmitter: Relays, DPDT

  • Certificates / Approvals

    ATEX, IEC Ex

  • Options

    Flange

  • Components

    Emiter: FQR50
    Transmitter: FTR325

  • Successor

    Soliwave FDR57

  • Application limits

    With waves emitted from outside (non-contact)
    Solid weight: <10g/l

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely
  • Seuraava malli