Levelflex M FMP40

Tuotekuva: Levelflex M FMP40

Tämä tuote ei enää ole saatavilla.

Tutustu uuteen sukupolveen edeltäjän / seuraavan mallin osiossa tai ota yhteyttä paikalliseen Endress+Hauser -edustajaan.

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Guided radar

  • Characteristic / Application

    Coaxial probe:
    not affected by nozzle dimensions or tank installations

    Rod probe:
    for measurement in highly viscous media

    Rope probe:
    large measurement range even with small process connection

  • Interface measurement

    Clean interfaces liquid / liquid

    Simultaneous measurment of interface and overall level

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Accuracy

    Coaxial probe: +/-3 mm (0.13")
    Rod probe: +/-3 mm (0.13")
    Rope probe: +/-3 mm (0.13"), >10m:0.03%

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 40 bar
    (Vacuum ... 580 psi)

  • Main wetted parts

    PTFE
    Coaxial probe: 316L, Alloy C22
    Rod probe: 316L, Alloy C22
    Rope probe: 316

  • Process connection

    G + NPT 3/4" and 1 1/2", DN40 ... DN150

  • Sensor length

    Rod: 4m (178")
    Coax: 4m (178")
    Rope: 35m (1378")

  • Application

  • Max. measurement distance

    Coaxial probe:
    4 m (178") Min. DK > 1.4
    Rod probe:
    4 m (178") Min. DK > 1.6
    Rope probe:
    35 m (1378") Min. DK > 1.6

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS
    WHG/ Overfill prevention
    SIL
    NACE
    GL Marine
    EN10204-3.1
    IECEx

  • Successor

    FMP50,FMP51

  • Application limits

    Horizontal storage tank cyl.:

    use coax probe

    Aggressive media:

    FMP41C

    Interface measurement:
    Use coax system in favor (coax probe,
    bypass, stilling well)

  • Mittausperiaate

    Guided radar

  • Characteristic / Application

    Powdered or granular solids
    Suitable for measurement with heavy dust production

  • Supply / Communication

    2-wire 16-36V, DC
    4-wire 10,5-32V, DC
    4-wire 90-250V, 50/60Hz

  • Ambient temperature

    -40 °C ... +80 °C
    (-40°F ... 176 °F)

  • Process temperature

    -40 °C ... +150 °C
    (-40°F ... 302°F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...40bar
    (Vaccum...580psi)

  • Main wetted parts

    316, PTFE

  • Process connection

    3/4" + 1-1/2" G+NPT
    Flange >=DN40

  • Blocking distance

    Top: 200mm (7.87")
    Bottom: 250mm (9.87") (Rope probe)

  • Sensor length

    Rod probe: 4m (13ft)
    Rope probe: 35m (115ft)

  • Max. measurement distance

    35m (115ft)

  • Communication

    4 ... 20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS
    WGH
    SIL
    NACE
    EN10204-3.1

  • Options

    Separate electronics, separate display

  • Successor

    FMP56, FMP57

  • Successor

    FMP56, FMP57

  • Application limits

    Dk <= 1,6

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely
  • Edeltäjä

  • Seuraava malli