Radiometric
Level and density measurement
Gammapilot FMG60

Gammapilot FMG60 stainless steel housing ©Endress+Hauser
Gammapilot FMG60 aluminum housing ©Endress+Hauser

Radiometric measuring principle

Gammapilot FMG60 application ©Endress+Hauser
Gammapilot FMG60 application ©Endress+Hauser

Compact transmitter for point level detection, continuous level, interface and density measurement

The Gammapilot FMG60 compact transmitter is made for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. The variable transmitter concept with NaJ crystal or plastic scintillators in different lengths guarantees optimum adaptation to individual applications. The transmitter contains a scintillator, photomultiplier and evaluation unit.

  • Benefits

    • Multifunctional compact transmitter: One instrument for all measuring tasks which results in cost savings in spare parts and maintenance

    • SIL2/3 approval in accordance with IEC 61508 for point level detection

    • Highest availability, reliability and safety,...

  • Field of application

    For liquids, solids, suspensions or sludges etc. Extreme measuring conditions, e.g. corrosiveness, toxicity, abrasion for all kinds of process vessels, e.g. reactors, autoclaves, separators, acid tanks, mixers, cyclones, cupola furnaces. Also for...

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • 20
    • Nr 20 Order code 52028420

      Cover FMG60, Ex ia (IS), 316L, gasket

      Material: 316L. O-ring 82.22x2.62 FKM Viton. Terminal compartment B, Ex ia (IS). Usage: FMG60.

    • Nr 20 Order code 71261143

      Cover FMG60, Ex ia (IS), Alu, gasket

      Material: aluminium. O-ring 82.22x2.62 FKM Viton. Terminal compartment B, Ex ia (IS). Usage: FMG60.

  • 25
    • Nr 25 Order code 52028467

      Cover FMG60, Ex d (XP), 316L, gasket

      Material: 316L. O-ring 82.22x2.62 FKM Viton. Terminal compartment A, Ex d (XP). Usage: FMG60.

    • Nr 25 Order code 71261142

      Cover FMG60, Ex d (XP) Alu, gasket

      Material: aluminium. O-ring 82.22x2.62 FKM Viton. Terminal compartment A, Ex d (XP). Usage: FMG60.

    • Order code 71002998

      Cooling tube FMG60, 316L, PVT L=800mm

      Mounting parts. Usage: FMG60.

    • Order code 71002999

      Cooling tube FMG60, 316L, PVT L=1200mm

      Mounting parts. Usage: FMG60.

    • Order code 71003001

      Cooling tube FMG60, 316L, PVT L=1600mm

      Mounting parts. Usage: FMG60.

    • Order code 71003005

      Cooling tube FMG60, 316L, NaI crystal

      L=50mm. Mounting parts. Usage: FMG60.

    • Order code 71003008

      Cooling tube FMG60, 316L, PVT L=200mm

      Mounting parts. Usage: FMG60.

    • Order code 71003009

      Cooling tube FMG60, 316L, PVT L=400mm

      Mounting parts. Usage: FMG60.

    • Order code 71003014

      Cooling tube FMG60, 316L, PVT L=2000mm

      Mounting parts. Usage: FMG60.

    • Order code 71071848

      Fixing cooling tube FMG60/FHG65

      Consists of: 2x flat ring 316. 6x hexagon screw M6x20 (FHG65). 6x cylinder head screw M6x20 (FMG60). O-ring 91.67x3.53 FKM. Usage: FHG65, FMG60.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code 71002997

      Collimator radial, NaI crystal

      Mounting parts. Usage: FMG60.

    • Order code 71034580

      Retainer 140mm, FHG60

      Consists of: pipe holder DN140. Rod holder. Usage: FHG60.

    • Order code 71034582

      Retainer 80mm, FHG60

      Consists of: pipe holder DN80. Rod holder. Usage: FHG60.

    • Order code 71034584

      Retainer 102mm, FHG60

      Consists of: pipe holder DN102. Rod holder. Usage: FHG60.

    • Order code 71034581

      Rod arm elbow, pipe retainer, FHG60

      Usage: FHG60.

    • Order code 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Order code FHX40-

      Display FHX40

      Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

Accessories, with links to our online product configurator

Back