Conductivity transmitter
Liquisys CLM253
Compact field device for all industries
Liquisys CLM253 is a standard transmitter for all analog conductivity sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
-
Benefits
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Broad functionality: Conductivity, resistivity and concentration measurement, ultrapure water monitoring according to USP and EP.
...
-
Field of application
The Liquisys CLM253 transmitter works with all analog conductivity sensors in non-hazardous areas, for example in these industries and their utilities:
Chemicals
Food & Beverages
Life Sciences
Power & Energy
Water &Wastewater
Primaries & Metal
...
Documents / Manuals / Software
-
Liquisys M CLM223/253
Technical Information
Transmitter for conductive and inductive sensors
Technical Information (TI) -
Liquisys M CLM223/253
Operating Instructions
Transmitter
Operating Instruction (BA) -
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
Operating Instruction (BA) -
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
Operating Instruction (BA) -
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)Ex Safety Instructions (XA) -
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Special Documentation (SD) -
Instructions for service kits Liquisis M
Special documents
Instructions for service kits Liquisis M / CPM253 / CLM253 / COM253 /
CUM253Special Documentation (SD) -
Installation of M 12 plug
Special Documentation Installation of M 12 plug
CPM253 / COM253 / CLM253 / CUM253Special Documentation (SD) -
Automatic control of disinfection
Field experience, absolute control of the chlorine and bisulphite
dosagesPublications (PU)11/07us -
Измерение электропроводимости и концентрации
Приборы промышленного анализа жидкости для измерения
проводимости и концентрации водных растворов.
Обзорная брошюра.Fields of Activities (FA)03/05Russian -
CIP system using conductivity maintains sanitary conditions
CIP (Clean-in-Place) is used in many operations to maintain sanitary
conditions in processesCase Studies (CS)06/07English -
Liquisys-M CLM253
1 Conductivity and temperature transmitters for conductive and inductive
measuring cellsTender Text09/05English -
Liquisys CLM253
Leitfähigkeits- und Temperatur Messumformer für konduktive und induktive
MesszellenTender Text06/16German -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1521_V02_04_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1521i)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.04.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1515_V02_30_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1515i)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.03.00Language neutral -
GSD Single, GSD_EH_DP_AN_Liquisys_0x1521_V02_03_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x1521c)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.03.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1515_V02_00_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1515c)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
DTM Single, LiquisysM_CLM2x3cond_PA_V2_30___V2_31, 10.07.2019 (Analysis, Liquisys M, 0x1515c)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3cond_DP_V2_30___V2_31, 10.07.2019 (Analysis, Liquisys M, 0x1521c)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3ind_PA_V2_30___V2_31, 10.07.2019 (Analysis, Liquisys M, 0x1515i)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_CLM2x3ind_DP_V2_30___V2_31, 10.07.2019 (Analysis, Liquisys M, 0x1521i)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysMCond_I_CLM2x3_V2_30, 09.07.2019 (Analysis, Liquisys M, 0x0092)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LiquisysMCond_C_CLM2x3_V2_30, 09.07.2019 (Analysis, Liquisys M, 0x0093)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Measurement of electrical conductivity
(.mp4 format, 70,7MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14fr -
Measurement of electrical conductivity
(.mp4 format, 116 MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14Polish -
Liquisys Chlorine, Liquisys Conductivity, Liquisys Oxygen, Liquisys pH/ORP
Product Code: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
Declaration Number: EC_00575_01.17EU DeclarationGerman , English , fr -
SmarTec S, SmarTec, Sensor, Memosens, Liquisys Conductivity, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, ANALOG
Product Code: CLM253-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS19-, CLS21-, CLS21D-, CLS30-, CLS50-, CLS50D-, CLS54-, CLS54D-, CLS82D-, CYM290-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-, CCS55D-, CCS51D-, CCS51-, CCS50D-, CCS50-, CCS241-, CCS240-, CCS142D-, CCS141-, CCS140-, CCS120D-, CCS120-
Region/Country: Russia (Declaration of Conformity)
Approval Number: EAEC RU D-DE.AD07.B.01363/19MiscellaneousRussian -
TOCII, Stip-Scan, Stamolys, Sensor, Mycom S, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Conductivity, Liquisys Chlorine, Liquiline M, Liquiline
Product Code: CPM253-, CPM223-, CPM153-, COM253-, COM223-, CM448-, CM444-, CM442-, CM14-, CLM253-, CLM223-, CLM153-, CCM253-, CCM223-, CAM74-, CA72TOC-, CA71SI-, CA71PH-, CA71NO-, CA71MN-, CA71HY-, CA71HA-, CA71FE-, CA71CU-, CA71CR-, CA71COD-, CA71CL-, CA71AM-, CA71AL-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-DE.MU62.B.02737MiscellaneousRussian -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, Memosens, SmarTec, SmarTec S
Product Code: CLS82D-, CLS54D-, CLS54-, CLS50D-, CLS50-, CLS30-, CLS21D-, CLS21-, CLS19-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-
Approval Number: EAEC RU D-DE.AD.07.B.01362/19MiscellaneousRussian -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, SmarTec S
Product Code: CLS54-, CLS52-, CLS50-, CLS30-, CLS21-, CLS19-, CLS16-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223-, CLD134-, CLD132-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.31.004.A_66843MetrologyRussian -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Product Code: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Nr 410 Order code 51501068
KIT CXM253 housing cover
-
-
-
Nr 335 Order code 71071446
Kit CxM253: Front foil + 6 key lifters
-
-
-
Nr 330,340,450a,450c Order code 51501073
KIT CXM253 Internal housing parts
-
-
-
Nr 400 Order code 51501072
KIT CXM253 bottom of housing
-
-
-
Nr 430 Order code 51501069
KIT CXM/153/253: 2 pair of hinges
-
-
-
Nr 403 Order code 51501087
KIT CXM253 Ground terminal strip
-
-
-
Nr 470 Order code 51501079
KIT CXM253 terminal strip power supply
-
-
-
Order code 50086842
Post mounting kit for LIQUISYS
for mounting the field-transmitters on horizontal or vertical pipes (max. diam. 60 mm). Material: stainless steel V2A
-
-
-
Nr 310 Order code 51501074
KIT CXM253 Ribbon cables
-
-
-
Nr 40 Order code 51501210
KIT CLM2x3 Central module I1 conductive
-
-
-
Nr 60 Order code 51501213
KIT CLM2X3 Conductive modul I1 HART
-
-
-
Nr 50 Order code 51501212
KIT CLM2X3 Conductive module I2
-
-
-
Nr 70 Order code 51501214
KIT CLM2X3 Conductive module I2 HART
-
-
-
Nr 80 Order code 51501215
KIT CLM2X3 cen. module Profibus PA cond.
-
-
-
Nr 90 Order code 51502502
Kit CLM2X3 central module ProfibusDPkond
-
Nr 90 Order code 71134726
Kit CLM2x3: Centralm. cond. PBDP;H/W2.1x
Content: 1x Central module Profibus DP Module name: LSCP-DP qualifired from H/W 2.10
-
-
-
Nr 290 Order code 71134732
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Content: 1x Relay module Profibus DP 2x Relay, 1x Current input DP connection qualified from H/W 2.10
-
-
-
Nr 40 Order code 51501216
KIT CLM2x3 inductive module I1
-
-
-
Nr 60 Order code 51501219
KIT CLM2x3 Inductive modul I1 HART
-
-
-
Nr 50 Order code 51501218
KIT CLM2x3 Inductive module I2
-
-
-
Nr 70 Order code 51501220
KIT CLM2x3 Inductive module I2 HART
-
-
-
Nr 80 Order code 51501221
KIT CLM2X3 cen. module Profibus PA ind
-
-
-
Nr 90 Order code 51502501
Kit CLM2X3 central module Profibus DPind
-
Nr 90 Order code 71134727
Kit CLM2x3: Centralm. ind. PBDP; H/W2.1x
Content: 1x Central module Profibus DP Module name: LSCP-DP qulaifired from H/W 2.10
-
-
-
Nr 240 Order code 71161133
Kit: MKIC Conductiv. transmitter Non-Ex
-
-
-
Nr 15 Order code 51500317
KIT CXM2X3 power supply 100..230 V AC
-
-
-
Nr 20 Order code 51500318
-
-
-
Nr 290 Order code 51511446
KIT CXM2X3 relay mod. 2rel / CSA
Upgrade of LIQUISYS-M basis version by 2 floating changeover contacts.
-
-
-
Order code 51500320
Kit CXM2X3 Relaismod. 2rel
Upgrade of LIQUISYS-M basis version by 2 floating changeover contacts.
-
-
-
Nr 300 Order code 51500321
Kit CXM2X3 Relaismodule 4rel
Upgrade of LIQUISYS-M basic version by 4 floating changeover contacts.
-
Nr 300 Order code 51511447
KIT CXM2X3 relay mod. 4rel / CSA
-
-
-
Nr 40 Order code 51504304
Kit CXM2X3 Relais Mod. 2rel.+I/CSA
Upgrade of LIQUISYS-M basic version by 2 contacts and current input 4-20mA.
-
-
-
Nr 45 Order code 51504305
Kit CXM2X3 Relais Mod. 4Rel+I/CSA
Upgrade of LIQUISYS-M basic version by 4 contacts and current input 4-20mA.
-
-
-
Order code 51500385
Upgrade "Plus-Package" for LIQUISYS-M
Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51500963
Upgrade cleaning for LIQUISYS-M
Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).
-
-
Predecessor