This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Level measurement, radar, non contact.
Application: liquids.
Rod antenna; 4-wire connection.
Aluminium housing, powder coated.
Current output Ex e/Ex ia selectable.
Volume calculation / Linearization.
Potential-free SPDT relais.
Easy set up procedure.
:: Independent of temperature/pressure
:: Independent of steam
:: Independent of gas layers
:: Pressure/gastight process separation
:: Safe on turbulent level surface
-
Characteristic / Application
Characteristic / Application
-
Supply / Communication
4-wire (HART/RS485)
-
Frequency
~6 GHz
-
Accuracy
+/- 10 mm
-
Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F) -
Process pressure / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi) -
Main wetted parts
PTFE
-
Process connection
DN80 ... DN150 / 3" ... 6"
-
Application
Application
-
Max. measurement distance
Max. measurement distance
-
Communication
4 ... 20 mA HART
Relay -
Certificates / Approvals
ATEX
FM
CSA
TIIS
3A -
Successor
test succ
-
Application limits
Application limits
-
-
Technical Information (TI)
Information technique Mesure de niveau par micro-ondes Micropilot FMR 131
-
Technical Information (TI)
French version - 06/2003New version available in EnglishTransmetteur smart pour la mesure sans contact dans des réservoirs de
stockage et de process, des cuves tampons.
Agréé pour l'utilisation en zones explosiblesLanguage:
French
Version:
01/06/2003
File size:
829.4 KB
File name:
TI252FFR.pdf
-
-
-
Operating Instruction (BA)
Micropilot FMR 130, FMR 131 Operating Instructions
-
Operating Instruction (BA)
English version - 06/2003New version available in EnglishSmart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for use in explosion hazardous
areas.EN 01/06/2003Language:
English
Version:
01/06/2003
File size:
994 KB
File name:
BA108FEN.PDF
-
-
-
Fieldbus Conformance
Product family: Micropilot I, Micropilot II, Micropilot M
-
Fieldbus Conformance
English version - 01/2008New version available in EnglishProduct root: FMR130-, FMR131-, FMR230-, FMR230V-, FMR231-,
FMR231E-, FMR240-, FMR245-, FMR250-
Region: International
Approval agency: PI, PROFIBUS International
Firmware Version: PROFILE 3.0
Process communication: PROFIBUS DPLanguage:
English
Version:
15/01/2008
File size:
1.2 MB
File name:
Z00629-Micropilot_M.pdf
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Micropilot 130 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
11/05/2023
File size:
228 MB
File name:
EH_Micropilot_I_FMR_13x_V1_5.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Micropilot 130 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
11/05/2023
File size:
228 MB
File name:
EH_Micropilot_I_FMR_13x_V2_1.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Micropilot 130 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
11/05/2023
File size:
228 MB
File name:
EH_Micropilot_I_FMR_13x_V2_0.zip
-