Multicap DC16ES
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Multicap DC 11/16/21/26 EN, Multicap DC 11/16/21/26 ESTechnical Information
Fully and partially insulated rod and rope probes for capacitive level measurement and limit detection
(European certificates).Technical Information (TI) -
Multicap DC 11/16/21/26 EN DC 11/16/21/26 ESOperating Instructions
Fully and partially insulated rod and rope probes for capacitive level measurement and limit detection (North American
certificates).Operating Instruction (BA) -
DCxx - echange of terminal module (FEC12)
Mulitcap probe DCxx - echange of terminal module (FEC12)
Short Instruction (KA)04/21German , English -
Safety Instructions
Probes and electronic inserts
II 1/2 G, II 2 G EEx ia IIC/IIB T6
PTB 98 ATEX 2215 X (ATEX)Ex Safety Instructions (XA) -
Probes and electronic inserts
Approval No.: EG 04 005-a
ATEX II 3 G
Protection:
EEx nA/nC II T6Ex Safety Instructions (XA) -
Safety Instructions
Probes and electronic inserts
II 1/2 G, II 2 G EEx ia IIC T6, EEx ia IIB T6
PBT 98 ATEX 2215 X (ATEX)Ex Safety Instructions (XA) -
Multicap
Capacitance level probes,
partially insulated
Approval No.: KEMA 00 ATEX 1036
ATEX II 1/2 D T80°C
Protection:
EEx ia IIC/IIBEx Safety Instructions (XA) -
Probes and electronic inserts
Approval No.: KEMA 99 ATEX 3122
ATEX II 2 G
ATEX 2(2) G
Protection:
EEx ia IIC T3...T6
EEx d[ia] IICT3...T6Ex Safety Instructions (XA) -
GSD Single, GSD_EH_PA_LE_Multicap_0x153A_V01_00_PALIB, 14.04.2014 (Level,
Multicap, 0x153A)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_Multicap_153A_0x03_0x01, 07.01.2019 (Level, Multicap, 0x153A)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Multicap_FEC14_V1_0, 21.10.2020 (Level, Multicap, 0x153A)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Multicap_FEC12_V1_0___1_2, 23.10.2020 (Level, Multicap, 0x0008)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral
Accessories / Spare parts
-
-
Order code
Phase out spares
-
Order code
Phase out repairs
-
Order code
12/2010
-
Order code 915653-0010
-
Order code 915653-0011
-
Order code 52014047
Sealing ring G1-1/2, 48x55 FA, 5 pcs.
Process gasket DIN7603-A. Usage: process connection, FMI21, FMI51/FMI52, FTI51/FTI52, FTI55, FTW31/FTW32, FMP51/FMP57, FMR60/FMR62/FMR67, Sliding sleeve G1-1/2 316L (52003665), 316L,3.1 (52011882), FTL51, FTL71,FTL81, AlloyC4 (52003666), FTL51, FTL71.
-
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-