FlexView FMA90 is a control unit for radar, ultrasonic and hydrostatic or universal 4-20 mA or HART level sensors. It connects up to two sensors simultaneously and provides 8 digital switching outputs for enhanced control. Available in field, DIN rail and panel housing variants, it ensures flexible installation in the field or control cabinet. Its robust design and intuitive touch operation make it ideal for water and wastewater as well as mining, minerals and metals applications.
FlexView FMA90 is suitable for a wide range of applications, providing clear visualization of measurement data and enhanced process control:
Open channel flow measurement
Remote water level and temperature monitoring
Pump control in water and wastewater treatment
Differential level measurement for rake control
Level monitoring in bulk solids storage
Crusher and conveyor belt monitoring
Edut
Flexible use with up to two level sensors across multiple measurement technologies and seamless system integration via HART or Modbus TCP
High cybersecurity in line with IEC 62443 and Endress+Hauser ProtectBlue product security framework
Remote access and parameterization at hard-to-reach measurement points via Wi-Fi and an integrated web server
Intuitive operation thanks to the 3.5" color touch display operable with gloves
Fast commissioning with automatic sensor detection and configuration via HART and guided setup sequences
Luotettava avoimen kanavan virtausmittaus jäteveden käsittelyssä FlexView FMA90- ja Micropilot FMR20B-tutka-anturilla luotettavaan virtauslaskentaan ja tiedonkeruuseen.
Steinenin jätevedenpuhdistamo modernisoi hulevesien ja suojarakennuksen altaan pinnan monitorointia FlexView FMA90:llä ja Micropilot FMR20B:llä näkyvyyden parantamiseksi ja toiminnan yksinkertaistamiseksi.
Älykäs pinnankorkeuteen perustuva pumpun ohjaus FlexView FMA90:lla ja Micropilot FMR20B:llä tai Waterpilot FMX21:llä toiminnan automatisointia ja pumpun suorituskyvyn optimointia varten vesi- ja jätevesisovelluksissa.
FlexView FMA90 ja Micropilot FMR20B -tutka-anturi tarjoavat reaaliaikaisen visualisoinnin, konfiguroitavan rajan monitoroinnin ja varhaisen ylikuormituksen tunnistuksen kuljetinhihnoille ja murskaimille.
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
Supply voltage
100 … 230 VAC; 10.5 … 32 VDC
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested); -35 to +60 °C (-31 to +140 °F) (approved by CSA)
Communication
Input: 1x or 2 x 4-20mA/HART Output: HART or Modbus TCP 1 or 2 x Analog, 1 relay or 5 relays (2 x SPDT, 3 x SPST), 1 or 3 open collector (NPN)
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC, UK
Specialities
Degree of protection of polycarbonate field housing; and aluminum field housing: IP65/NEMA Type 4x; Degree of protection of DIN rail housing: IP20; Degree of protection of panel housing: IP65/NEMA Type 4 (at front,; if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door); sensor recognition and parameter mapping; of FMR20B/FMR30B/FMX21 sensors
Mittausperiaate
Level radar
Characteristic / Application
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
Specialities
Degree of protection of polycarbonate field housing; and aluminum field housing: IP65/NEMA Type 4x; Degree of protection of DIN rail housing: IP20; Degree of protection of panel housing: IP65/NEMA Type 4 (at front,; if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door); sensor recognition and parameter mapping; of FMR20B/FMR30B/FMX21 sensors
Supply / Communication
100 … 230 VAC; 10.5 … 32 VDC
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested); -35 to +60 °C (-31 to +140 °F) (approved by CSA)
Communication
Input: 1x or 2 x 4-20mA/HART Output: HART or Modbus TCP, 1 or 2 x Analog, 1 relay or 5 relays (2 x SPDT, 3 x SPST), 1 or 3 open collector (NPN)
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC, UK
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, Guided wizards for easy commissioning, Up to two level sensors Housing: Panel-mounted / DIN rail / Field
Degree of protection of polycarbonate field housing; and aluminum field housing: IP65/NEMA Type 4x; Degree of protection of DIN rail housing: IP20; Degree of protection of panel housing: IP65/NEMA Type 4 (at front,; if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door); sensor recognition and parameter mapping; of FMR20B/FMR30B/FMX21 sensors
Supply / Communication
100 … 230 VAC; 10.5 … 32 VDC
Ambient temperature
–40 to +60 °C (–40 to +140 °F) (Type tested); –35 to +60 °C (–31 to +140 °F) (approved by CSA)
Communication
Input: 1x or 2 x 4-20mA/HART Output: HART or Modbus TCP, 1 or 2 x Analog, 1 relay or 5 relays (2 x SPDT, 3 x SPST), 1 or 3 open collector (NPN)
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC, UK
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, Guided wizards for easy commissioning, Up to two level sensors Housing: Panel-mounted / DIN rail / Field
Ohjausyksikkö jossa värinäyttö ja kosketustoiminto jopa kahdelle ultraääni-, tutka-, hydrostaattiselle tai yleismalliselle 4-20 mA/H ART® -pinta-anturille
Käytämme evästeitä parantaaksemme selauskokemustasi, kerätäksemme tilastoja sivuston toiminnan optimoimiseksi ja toimittaaksemme räätälöityjä mainoksia tai sisältöä.