Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen
Memosens Wave CAS80E offers reliable real-time measurements of relevant analytical parameters such as chemical and biological oxygen demand (COD, BOD), turbidity, nitrate and spectral absorption coefficient (SAC) in one single device. It thus increases your efficiency and minimizes costs for your measuring points. The compact, handy Memosens Wave CAS80E spectrometer is easy to install and maintain and ensures reliable, interference-free communication thanks to Memosens digital technology.
The Memosens Wave CAS80E spectrometer is suitable for measuring a wide range of analytical parameters in:
Drinking water
Surface water
Wastewater
Industrial wastewater
Utilities
Edut
Ensures uninterrupted measurements in real time by operating directly in the process.
Benefit from reliable, interference-free communication thanks to Memosens digital technology.
Offers you the analysis of many standard parameters for your water and wastewater monitoring. Measures your specific selection of the parameters turbidity, suspended solids, CODeq, BODeq, TOCeq, SAC254, nitrate and the APHA-Hazen color.
The spectrometer is quickly adapted to your specific application through pre-installed analysis models.
Compact, lightweight spectrometer that is very easy to install and convinces with its low-maintenance operation.
Tampereen Vesi luottaa Endress+Hauserin mittauksiin ja palveluihin sekä talousveden tuotannossa että jätevedenpuhdistuksessa. Tesoman vesitornissa käyttöönotettu analyysipaneeli on ensimmäinen laatuaan Suomessa.
AVR Waste Botlekissa Rotterdamissa prosessoi jopa 1,7 miljoonaa tonnia jätevettä vuodessa. Tutustu, miten yritys optimoi pH-mittauksensa Endress+Hauserin avulla
Meriveden käyttäminen käymälöiden huuhteluun voi säästää suuren määrän juomavettä. Jatkuvan vedensaannin varmistamiseksi käytössä olevien antureiden on toimittava luotettavasti, jotta veden laatutavoitteet täyttyvät.
Monitoring of WWTP in- and outlet Drinking water and surface water
Installation
Insitu (immersion in process), extractive with sample and flow cell
Characteristic
Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color
Measuring range
"Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen
Measuring principle
UV/VIS absorbance at 200 to 800 nm
Design
40 mm
Material
Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM
Dimension
571.4 x 40 mm 21.5 x 1.6 in
Process temperature
0 to 50°C 32 to 122 °F
Process pressure
0.5 to 10 bar abs. 7.3 to 145 psi
Temperature sensor
-20 to 60°C -4 to 140 °F
Connection
G1 and NPT 3/4"
Ingress protection
IP68
Mittausperiaate
UV absorbance
Application
Monitoring of WWTP in- and outlet, drinking water and surface water
Characteristic
Insitu (immersion in process) Extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color
Measuring range
Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen
Design
40 mm
Material
Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM
Process temperature
0 to 50°C 32 to 122 °F
Process pressure
0.5 to 10 bar abs. 7.3 to 145 psi
Temperature sensor
-20 to 60°C -4 to 140 °F
Connection
G1 and NPT 3/4"
Ingress protection
IP68
Mittausperiaate
UV absorbance
Characteristic
Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color
Measuring method
UV/VIS Absorbance at 200 to 800 nm
Size
571.4 x 40 mm 21.5 x 1.6 in
Design
40 mm
Process temperature
0 to 50°C 32 to 122 °F
Ambient temperature
-20 to 60°C -4 to 140 °F
Process pressure
0.5 to 10 bar abs. 7.3 to 145 psi
Specials
G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60 days
Application
Monitoring of WWTP in- and outlet Drinking water and surface water
Measuring range
Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen
This instruction applies to following spare part kits: 71504608 Kit CA80TN High power board 71504609 Kit CA80TN Photometer CPU 71504610 Kit CA80TN Connection board photometer 71503214 Kit CA80TN Control module
Käytämme evästeitä parantaaksemme selauskokemustasi, kerätäksemme tilastoja sivuston toiminnan optimoimiseksi ja toimittaaksemme räätälöityjä mainoksia tai sisältöä.