Kokeile etsiä avainsanoilla, tuote- tai tilauskoodilla tai sarjanumerolla, esim. "CM442" tai "tekniset tiedot"
Aloita haku syöttämällä vähintään 2 merkkiä.
Micropilot NMR84 - Radar

Radar measurement
Micropilot NMR84

For high accurate non-contact level measurement in stilling well applications in custody transfer

NMR84
Please Wait (spinning wheel)
Lataa hintaa
Hintoja ei tilap. saatavilla
Price on request
from CHF ??.-
Suodata mittaus-/sovellustehtävä
Mittaus / sovellustehtävä

Konfiguroi ladataksesi tämän tuotteen CAD-kuvat

  • Mittausperiaate

    Level radar

  • Characteristic / Application

    Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30 m (98ft)

  • Specialities

    Custody transfer level measurement

  • Supply / Communication

    85-264VAC
    52-74VAC
    19-64VDC

  • Accuracy

    up to 0.5 mm

  • Ambient temperature

    Standard:
    -40°C…60°C
    (-40°F...140°F)
    For calibration to regulatory
    standards:
    -25°C…55°C
    (-13°F...131°F)

  • Process temperature

    -40°C…150°C
    (-40°F...302°F)

  • Process pressure / max. overpressure limit

    Vacuum ... 25 bar abs

  • Main wetted parts

    316L, PTFE

  • Process connection

    Flange:
    DN100/4"…DN300/12"
    UNI-Flange:
    DN150/6"…DN300/12"

  • Max. measurement distance

    40 m (131 ft)
    For calibration to regulatory standards:
    30 m (98 ft)

  • Communication

    Outputs:
    Fieldbus: Modbus RS485, V1, WM550
    HART, BPM and TRL/2 (via GE option)
    Analog 4-20mA output (Exi/ Exd)
    Relay output (Exd)
    Inputs:
    Analog 4-20mA input (Exi/ Exd)
    2-, 3-, 4-wire RTD input
    Discrete input (Exd, passive/ active)

  • Certificates / Approvals

    ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
    INMETRO, NEPSI, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    AD2000

  • Metrological approvals and certificates

    OIML, NMi, PTB

  • Options

    Redundant fieldbus
    Alu-coated or 316L housing
    Weather protection cover

  • Application limits

    Maximum measuring range is
    dependent on the tank form and/
    or application
    Strong condensate or build-up
    formation