Kokeile etsiä avainsanoilla, tuote- tai tilauskoodilla tai sarjanumerolla, esim. "CM442" tai "tekniset tiedot"
Aloita haku syöttämällä vähintään 2 merkkiä.

Proline Prosonic Flow 92F
Ultrasonic flowmeter

Picture of ultrasonic flowmeter Proline Prosonic Flow 92F for the chemical & petrochemical industry ©Endress+Hauser

Proline Prosonic Flow 92F - Ideally suited for the chemical and petrochemical industries

The Ultrasonic Flow Measuring Principle

Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs

Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.

  • Helppokäyttöiset tuotteet

  • Helpot valita, asentaa ja käyttää

Tekninen suorituskyky

Helppokäyttöisyys

  • Standardituotteet

  • Luotettavat, lujatekoiset, helppohoitoiset

Tekninen suorituskyky

Helppokäyttöisyys

  • Huippulaatuiset tuotteet

  • Erityisen toiminnalliset ja miellyttävät

Tekninen suorituskyky

Helppokäyttöisyys

  • Erikoistuotteet

  • Suunniteltu vaativiin sovelluksiin

Tekninen suorituskyky

Helppokäyttöisyys

Variabel

FLEX-valikoima Tekninen suorituskyky Helppokäyttöisyys
  • F
  • L
  • E
  • X

Fundamental-valikoima

Täytä perusmittaustarpeesi

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Lean-valikoima

Käsittele ydinprosessejasi helposti

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Extended-valikoima

Optimoi prosessisi innovatiivisilla teknologioilla

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Xpert-valikoima

Hallitse haastavimmatkin sovelluksesi

Tekninen suorituskyky
Helppokäyttöisyys

Variabel

  • Tärkeimmät tekniset tiedot

    • Max. measurement error

      Volume flow (standard):
      - ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
      Volume flow (option):
      - ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

    • Measuring range

      0.5 to 10 m/s (1.6 to 33 ft/s)

    • Medium temperature range

      -40 to +150 °C (-40 to +302 °F)
      -40 to +200 °C (-40 to +392 °F) optional

    • Max. process pressure

      PN 40 / ASME Cl. 300 / JIS 20K

    • Wetted materials

      Sensor:
      A351-CF3M (DN25 to 100)
      1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
      Transducer: 1.4404/316/316L
      Flanges : 1.4404/316/316L or A105/1.0432

please wait Loading alternative products

Pikavalinta

Tee valinta ehdotetuista vaihtoehdoista
Myyntihinta
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

tai

Yksilöllinen konfiguraattori

Jatka valintaa kaikista mahdollisista vaihtoehdoista
  • Edut

    • Safe design for process industries – international hazardous area approvals

    • No additional pressure loss – full-bore design

    • Process transparency – diagnostic capability

    • Easy installation and reduced installation costs – loop-powered transmitter

    • Fully...

  • Käyttöalue

    • The measuring principle is independent of pressure, density, temperature, conductivity and viscosity

    • Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

    Device properties:

    • Full compliance...

Ominaisuudet ja tiedot

Takaisin

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Ultrasonic flow

  • Product headline

    Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
    Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.

  • Sensor features

    Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
    Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F).

  • Transmitter features

    Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing.
    Device as compact or remote version. 2-line backlit display with push buttons. HART, PROFIBUS PA, FOUNDATION Fieldbus.

  • Nominal diameter range

    2 path version: DN80 to 300 (3 to12")
    3 path version: DN25 to 50 (1 to 2")
    4 path version: DN 80 to 300 (3 to 12")

  • Wetted materials

    Sensor:
    A351-CF3M (DN25 to 100)
    1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
    Transducer: 1.4404/316/316L
    Flanges : 1.4404/316/316L or A105/1.0432

  • Measured variables

    Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength

  • Max. measurement error

    Volume flow (standard):
    - ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
    Volume flow (option):
    - ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

  • Measuring range

    0.5 to 10 m/s (1.6 to 33 ft/s)

  • Max. process pressure

    PN 40 / ASME Cl. 300 / JIS 20K

  • Medium temperature range

    -40 to +150 °C (-40 to +302 °F)
    -40 to +200 °C (-40 to +392 °F) optional

  • Ambient temperature range

    -40 to +60 °C (-40 to +140 °F) compact
    -40 to +80 °C (-40 to +176 °F) remote sensor
    -40 to +60 °C (-40 to +140 °F) remote transmitter

  • Transmitter housing material

    AlSi10Mg, coated

  • Degree of protection

    IP67, type 4X enclosure
    IP68 type 6P enclosure (option for remote)

  • Display/Operation

    2 lines backlit display with 3 push buttons

  • Outputs

    1x 4-20 mA HART
    1x Pulse/frequency/switch output (passive)

  • Inputs

    N/A

  • Digital communication

    HART, Profibus PA, FOUNDATION Fieldbus

  • Power supply

    2 wire loop powered

  • Hazardous area approvals

    ATEX,FM, CSA, JPN

  • Other approvals and certificates

    3.1 material (wetted parts), calibration performed on accredited
    calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
    PED, EAC marking

  • Product safety

    EAC marking

  • Metrological approvals and certificates

    calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    CRN, PED, AD2000

  • Material certificates

    3.1 material (wetted parts)

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely