Kokeile etsiä avainsanoilla, tuote- tai tilauskoodilla tai sarjanumerolla, esim. "CM442" tai "tekniset tiedot"
Aloita haku syöttämällä vähintään 2 merkkiä.

Proline Promass Q 500
Coriolis flowmeter

Picture of Coriolis flowmeter Proline Promass Q 500 / 8Q5B with different remote transmitters ©Endress+Hauser

Proline Promass Q 500 with different remote transmitters

Coriolis flowmeter - Proline Promass Q 500 ©Endress+Hauser

Proline Promass Q 500

Proline Promass Q optimizes measurement in receiving of raw milk with unwanted entrained air at the dairy Meierei Barmstedt

German Innovation Award 2018 GOLD

The German Innovation Award recognizes industry-wide products that set themselves apart from currently-available solutions through their added value.

The Coriolis Flow Measuring Principle

Proline Promass Q - The flow specialist for the exact measurement of liquids with entrained gas

The innovative specialist for challenging applications, as remote version with up to 4 I/Os

Promass Q 500 provides the highest measurement accuracy for mass flow, volume flow and density. Being the preferred choice for custody transfer applications, it has also been optimized for liquid applications where entrained gas is known to be present. With its innovative remote transmitter Promass Q 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.

  • Helppokäyttöiset tuotteet

  • Helpot valita, asentaa ja käyttää

Tekninen suorituskyky

Helppokäyttöisyys

  • Standardituotteet

  • Luotettavat, lujatekoiset, helppohoitoiset

Tekninen suorituskyky

Helppokäyttöisyys

  • Huippulaatuiset tuotteet

  • Erityisen toiminnalliset ja miellyttävät

Tekninen suorituskyky

Helppokäyttöisyys

  • Erikoistuotteet

  • Suunniteltu vaativiin sovelluksiin

Tekninen suorituskyky

Helppokäyttöisyys

Variabel

FLEX-valikoima Tekninen suorituskyky Helppokäyttöisyys
  • F
  • L
  • E
  • X

Fundamental-valikoima

Täytä perusmittaustarpeesi

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Lean-valikoima

Käsittele ydinprosessejasi helposti

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Extended-valikoima

Optimoi prosessisi innovatiivisilla teknologioilla

Tekninen suorituskyky
Helppokäyttöisyys
  • F
  • L
  • E
  • X

Xpert-valikoima

Hallitse haastavimmatkin sovelluksesi

Tekninen suorituskyky
Helppokäyttöisyys

Variabel

  • Tärkeimmät tekniset tiedot

    • Max. measurement error

      Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
      Volume flow (liquid): ±0.10 %
      Mass flow (gas): ±0.35 %
      Density (liquid): ±0.2 kg/m³

    • Measuring range

      0 to 400 000 kg/h (0 to 14 697 lb/min)

    • Medium temperature range

      Standard: –50 to +205°C (–58 to +401 °F)
      Option: –196 to +150 °C (–321 to +302 °F)

    • Max. process pressure

      PN 100, Class 600, 63K

    • Wetted materials

      Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
      Connection: 1.4404 (316/316L)

please wait Loading alternative products

Pikavalinta

Tee valinta ehdotetuista vaihtoehdoista
Myyntihinta
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

tai

Yksilöllinen konfiguraattori

Jatka valintaa kaikista mahdollisista vaihtoehdoista
  • Edut

    • Secured measuring quality – unmatched accuracy of mass flow, volume flow and density

    • Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology)

    • Fewer process measuring points – multivariable measurement (flow, density,...

  • Käyttöalue

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Highest measurement performance for custody transfer, density and under tough process conditions.

    Device properties

    • Mass flow: measurement error ±0.05...

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 400 000 kg/h (0 to 14 697 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 40 to +60 °C (–40 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)

  • Marine approvals and certificates

    LR approval, DNV GL approval, ABS approval, BV approval

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Mittausperiaate

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Marine approvals and certificates

    LR approval, DNV GL approval, ABS approval, BV approval

  • Mittausperiaate

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 400 000 kg/h (0 to 14 697 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 4 to +60 °C (–4 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)

  • Marine approvals and certificates

    LR approval, DNV GL approval, ABS approval, BV approval

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Mittausperiaate

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 550 000 kg/h (0 to 20 210 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 4 to +60 °C (–4 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)
    MC (Liquids other than water, Cryogenic liquids)

  • Marine approvals and certificates

    LR approval, DNV GL approval, ABS approval, BV approval

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Mittausperiaate

    Coriolis

  • Product Headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os.
    Secured measuring quality – unmatched accuracy of mass flow, volume flow and density.
    Highest measurement performance for custody transfer, density and under tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
    Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 550 000 kg/h (0 to 20 210 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 40 to +60 °C (–40 to +140 °F)
    Option:–50 to +60 °C (–58 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input

    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Other approvals and certificates

    CE, C-tick, EAC marking

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511


    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)
    MC (Liquids other than water, Cryogenic liquids)


    LR approval, DNV GL approval, ABS approval, BV approval

    PED, CRN, AD 2000


    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK


    3-A, EHEDG, cGMP

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely
  • 31
  • 47
  • 36
  • 33
  • 39
  • 34
  • 37
  • 46
  • 35
  • 45
    • Nro 45 Tilauskoodi 71323075

      Kit conn.terminal option A, 300/500, Ex

      Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.

  • 50
  • 45
    • Nro 45 Tilauskoodi 71323076

      Kit conn.terminal option B, 300/500, Ex

      Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.

    • Nro 45 Tilauskoodi 71327819

      Kit conn.terminal option C, 300/500, Ex

      Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.

    • Nro 45 Tilauskoodi 71323077

      Kit terminal option A, 500 dig., Non-haz

      Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.

    • Nro 45 Tilauskoodi 71323078

      Kit terminal option B, 500 dig., Non-haz

      Usage: transmitter housing Alu/polycarbonate, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.

    • Nro 45 Tilauskoodi 71327820

      Kit terminal option C, 500 dig., Non-haz

      Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.

  • 44
  • 20
    • Nro 20 Tilauskoodi 71323016

      Kit cover, sight glass, Alu,Non-haz/Exde

      Usage: Promag/Promass/Prosonic Flow/t-mass 300, Prosonic Flow 500, transmitter housing Alu, Non-haz. Promag/Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110.7x3.53 HNBR.

    • Nro 20 Tilauskoodi 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 20 Tilauskoodi 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 20 Tilauskoodi 71323020

      Kit cover, sight glass, Alu, Exd

      Usage: Promag/Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110.7x3.53 HNBR.

    • Nro 20 Tilauskoodi 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 20 Tilauskoodi 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 20 Tilauskoodi 71323024

      Kit cover, sight glass, cast, Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover sight glass, cast, O-Ring 110.7x3.53 HNBR.

    • Nro 20 Tilauskoodi 71323025

      Kit cover, sight glass, cast, -50oC, Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 20 Tilauskoodi 71323025

      Kit cover, sight glass, cast, -50oC, Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

  • 70
    • Nro 70 Tilauskoodi 71323026

      Kit cover gasket, sight glass/blind

      Usage: Promag/Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.

    • Nro 70 Tilauskoodi 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

    • Nro 70 Tilauskoodi 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.

  • 22
    • Nro 22 Tilauskoodi 71323032

      Kit cover, electronic compart., Alu, Ex

      Usage: Promag/Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.

    • Nro 22 Tilauskoodi 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

    • Nro 22 Tilauskoodi 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

    • Nro 22 Tilauskoodi 71323034

      Kit cover, electronic compart., cast, Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.

    • Nro 22 Tilauskoodi 71323035

      Kit cover, electr.compart.,cast,-50oC,Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

    • Nro 22 Tilauskoodi 71323035

      Kit cover, electr.compart.,cast,-50oC,Ex

      Usage: Promass/Prosonic Flow 300, Promag/Promass/Prosonic Flow 500, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

  • 74
    • Nro 74 Tilauskoodi 71323036

      Kit cover gasket, electronic compart.,Ex

      Usage: Promag/Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.

    • Nro 74 Tilauskoodi 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

    • Nro 74 Tilauskoodi 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Usage: Promass/Prosonic Flow/t-mass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

  • 23
    • Nro 23 Tilauskoodi 71323038

      Kit cover, wall mount, Alu, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.

    • Nro 23 Tilauskoodi 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

    • Nro 23 Tilauskoodi 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

    • Nro 23 Tilauskoodi 71323040

      Kit cover, wall mount, cast, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 HNBR.

    • Nro 23 Tilauskoodi 71323041

      Kit cover, wall mount, cast, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

    • Nro 23 Tilauskoodi 71323041

      Kit cover, wall mount, cast, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

  • 75
    • Nro 75 Tilauskoodi 71323042

      Kit cover gasket, wall mount, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.

    • Nro 75 Tilauskoodi 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

    • Nro 75 Tilauskoodi 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Usage: Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.

  • 20
    • Nro 20 Tilauskoodi 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.

    • Nro 20 Tilauskoodi 71408508

      Kit cover, polycarb., 500 digital,800(C)

      Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.

  • 70
    • Nro 70 Tilauskoodi 71278078

      Kit cover gasket, alu,400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.

    • Nro 70 Tilauskoodi 71278077

      Kit 10 cover gasket, polycarbonate

      Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.

  • 24
    • Nro 24 Tilauskoodi 71228796

      Kit cover, remote, Alu

      Usage: Promag 10/500, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.

    • Nro 24 Tilauskoodi 71323050

      Kit cover, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.

    • Nro 24 Tilauskoodi 71323050

      Kit cover, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.

  • 73
    • Nro 73 Tilauskoodi 71323051

      Kit housing gaskets, remote, Alu

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor.

    • Nro 73 Tilauskoodi 71323052

      Kit housing gaskets, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323052

      Kit housing gaskets, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323052

      Kit housing gaskets, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

  • 24
    • Nro 24 Tilauskoodi 71323053

      Kit cover, remote, stainless 1.4301

      Usage: Promass 500, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.

    • Nro 24 Tilauskoodi 71323054

      Kit cover, remote,stainless 1.4301,-50oC

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.

    • Nro 24 Tilauskoodi 71323054

      Kit cover, remote,stainless 1.4301,-50oC

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.

  • 73
    • Nro 73 Tilauskoodi 71323057

      Kit housing gaskets, remote, stainless

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.

    • Nro 73 Tilauskoodi 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

  • 24
    • Nro 24 Tilauskoodi 71185793

      Kit cover,ultra compact,stainless 1.4301

      Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.

    • Nro 24 Tilauskoodi 71323060

      Kit cover, ultra compact, 1.4301, -50oC

      Usage: Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.

    • Nro 24 Tilauskoodi 71323060

      Kit cover, ultra compact, 1.4301, -50oC

      Usage: Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.

  • 73
    • Nro 73 Tilauskoodi 71185799

      Kit hous.gaskets,ultra compact,stainless

      Usage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.

    • Nro 73 Tilauskoodi 71323062

      Kit housing gasket, ultra compact, -50oC

      Usage: Promass 500 digital, sensor connection housing stainless. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323062

      Kit housing gasket, ultra compact, -50oC

      Usage: Promass 500 digital, sensor connection housing stainless. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

    • Nro 73 Tilauskoodi 71323062

      Kit housing gasket, ultra compact, -50oC

      Usage: Promass 500 digital, sensor connection housing stainless. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

  • 24