Developed according to industry standards for single-use sensors, this Raman optic system is cGMP qualified and gamma sterilizable. The system is comprised of two parts - a reusable optic and a disposable fitting for single-use bioreactors (SUB). The Raman optic system for single use in conjunction with the Rxn-10 probe offers the same quality data as reusable Raman probes. This ability allows customers to develop products and processes without limitations of the final production reactor type.
Ramanin kalibrointi- ja verifiointisarjat - Kaikki, mitä tarvitaan Raman-analysaattorijärjestelmän kalibroimiseen ja verifiointiin laboratoriosta prosessiin -skaalattavuutta varten
Accessory optics for the Rxn-10 probe Technical Information
Englanti - 07/2026
New version available in English
System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
Accessory optics for the Rxn-10 probe Technical Information
Tekniset tiedot (TI)
Englanti - 07/2026
New version available in English
System design and specifications for Rxn-10 probe optics: Raman immersion optics (KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves (KRBSL), and Raman optic system for single use (KRSU1)
Accessory optics for the Rxn-10 probe Operating Instructions
Käyttöohje (BA)
Englanti - 06/2026
New version available in English
Commissioning, operation, and maintenance details for Rxn-10 probe optics: Raman immersion optics (KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic (KRBMO), bio sleeve (KRBSL), and Raman optic system for single use (KRSU1)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Lyhyt ohje (KA)
Englanti - 06/2026
New version available in English
Quick start guide for Rxn-10 probe optics: Raman immersion optics (KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves (KRBSL), and Raman optic system for single use (KRSU1)
Bioprocessing infrastructure readiness for online analytical
instrumentation integration - Is your upstream operation ready for
seamless deployment of an online Raman spectroscopy system?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps pharmaceutical and API manufacturers evaluate their readiness for implementing online Raman spectroscopy. A simple scoring system identifies potential infrastructure, integration, and process monitoring challenges, helping teams assess deployment complexity and prepare for successful real-time analytical monitoring.
Analytical costs, scale-up delays, and optimization potential in
upstream bioprocessing - Is your upstream process costing more than
you think?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps bioprocessing teams evaluate analytical costs and delays associated with scaling up from laboratory development to production. A scoring system helps identify optimization opportunities and assess the value of real-time monitoring using online Raman spectroscopy.
Graphic illustrating the core elements of Biopharma 4.0 including product lifecycle stages, role of PAT/QbD, and 12 key advanced technologies for scientists and process engineers in the Life Sciences, applicable to Raman spectroscopy systems (Raman Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve, flow cell and flow bench, Raman optic system for single use, and Raman calibration & verification kits).
This guide explains Raman spectroscopy implementation in GMP-regulated pharmaceutical and biopharmaceutical manufacturing, covering qualification, validation, data integrity, supplier and user responsibilities, and risk-based compliance approaches for process analytical technology applications.
Raman application guide for the life science industry -
Trusted composition analysis for the life sciences
PU (julkaisu)
Englanti - 04/2022
New version available in English
A guide to our Raman spectroscopy application notes for the Life Science industry (featuring the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic, non-contact optic).
Prioritize scalability for an efficient biopharmaceutical
product development lifecycle
PU (julkaisu)
Tšekki - 09/2024
New version available in English
This technical paper studies the importance of scalability as a competitive advantage in bioprocessing in the Life Science industry, and Endress+Hauser's scalable Raman systems (Raman Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve, flow cell and flow bench, Raman optic system for single use) and liquid analysis sensor technology and Liquid Analysis portfolio (Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E, CLS82E).
Real-time analytical control of your API synthesis process - Is your
API crystallization process truly under control between lab analyses?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps API synthesis teams in the Life Sciences industry identify analytical blind spots and assess the value of real-time inline Raman spectroscopy for monitoring API crystallization processes.
Analytical blind spots and contamination risks in upstream
bioprocessing - Are your cell cultures truly under control between
measurements?
PU (julkaisu)
Englanti - 08/2026
New version available in English
This self-assessment questionnaire helps cell culture and upstream bioprocessing teams identify analytical blind spots, contamination risks from manual sampling, and opportunities to improve process control through real-time monitoring. A simple scoring system highlights where online Raman spectroscopy may help improve data quality, reduce risk, and support faster process decisions.
Raman-Anwendungsleitfaden für die
Life-Sciences-Industrie
PU (julkaisu)
Saksa - 09/2025
New version available in English
Ein Leitfaden zu unseren Anwendungshinweisen zur Raman-Spektroskopie für die Life-Science-Industrie (Raman Rxn2-Analysator, Raman Rxn4-Analysator, Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde, Rxn-46-Sonde und Zubehör für Sondenoptiken (blO-Optic, Raman- Single Use-Optiksystem / SUB, Immersionsoptik, berührungslose Optik)
Expanded version of a graphic illustrating the core elements of Biopharma 4.0 including product lifecycle stages, role of PAT/QbD, and 12 key advanced technologies for scientists and process engineers in the Life Sciences, applicable to Raman spectroscopy systems (Raman Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve, flow cell and flow bench, Raman optic system for single use, and Raman calibration & verification kits).
With non-contact and immersion optic: 532 nm, 785 nm, 1000 nm With bIO-Optic or Raman optic system for single use: 785 nm, 1000 nm With bio multi optic and bio sleeve or Raman flow assembly: 785 nm
With non-contact and immersion optic: 532 nm, 785 nm, 1000 nm With bIO-Optic or Raman optic system for single use: 785 nm, 1000 nm With bio multi optic and bio sleeve or Raman flow assembly: 785 nm
Käytämme evästeitä parantaaksemme selauskokemustasi, kerätäksemme tilastoja sivuston toiminnan optimoimiseksi ja toimittaaksemme räätälöityjä mainoksia tai sisältöä.