Tärkeimmät tekniset tiedot
-
Input
2 x universal (U, I, R, RTD, TC)
-
Output
1 x loop power supply
-
Output
2 x analogue output (I, U)
1 x loop power supply -
Display
Multicolor backlight LCD
White/black/yellow
Bargraph
Unit
TAG
Alarm warning in plain text -
Power Supply
20...250V AC/DC
Käyttöalue
Analog measured values are indicated, evaluated and calculated by the process meter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.
The RIA45 panel meter exhibits a display, analog inputs for process and status signals, analog and digital outputs, and an interface for configuration. Connected sensors can be powered by the integrated LPS. All measured and calculated values are available as a signal source for display, outputs, relays and the interface.
Plant and apparatus engineering and construction
Control rooms and cabinets
Laboratories
Process recording and supervision
Process control
Signal adjustment and conversion
Edut
-
5-digit 7-segment LC display, backlit
-
1 or 2 universal inputs
-
2 relays (optional)
-
Min./max. value saved
-
1 or 2 calculated values and linearization table
-
Digital status output (Open Collector)
SIL2 approval (optional); marine approval
Lean-valikoima
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys

-
Helppokäyttöiset tuotteet
- Helppoja valita, asentaa ja käyttää
Tekninen suorituskyky
Helppokäyttöisyys
-
Standardituotteet
- Luotettavat, lujatekoiset ja helppoja huoltaa
Tekninen suorituskyky
Helppokäyttöisyys
-
Laadukkaat tuotteet
- Erinomainen toiminnallisuus
Tekninen suorituskyky
Helppokäyttöisyys
-
Erikoistuotteet
- Suunniteltu vaativiin sovelluksiin
Tekninen suorituskyky
Helppokäyttöisyys
Tuotekohtainen
FLEX-valikoima | Tekninen suorituskyky | Helppokäyttöisyys |
---|---|---|
Fundamental-valikoima Täytä perusmittaustarpeesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Lean-valikoima Käsittele ydinprosessejasi helposti |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Extended-valikoima Optimoi prosessisi innovatiivisilla teknologioilla |
Tekninen suorituskyky
|
Helppokäyttöisyys
|
Xpert-valikoima Hallitse haastavimmatkin sovelluksesi |
Tekninen suorituskyky
|
Helppokäyttöisyys
Tuotekohtainen |
Edeltäjä
-
-
Technical Information (TI)
RIA45
Process indicator
EN FI 30/06/202210/03/201602/11/201525/04/201429/10/2012Kieli:
Englanti
Versio:
30/06/2022
Tiedoston koko:
753.8 KB
Tiedoston nimi:
TI00141REN_0622-00.pdf
-
-
-
Operating Instruction (BA)
RIA45
Process indicator
EN FI 30/06/202210/03/201615/10/201525/04/201430/01/2014Kieli:
Englanti
Versio:
30/06/2022
Tiedoston koko:
1.5 MB
Tiedoston nimi:
BA00272REN_0722-00.pdf
-
-
-
Short Instruction (KA)
RIA45 Lyhyt käyttöopas
Lyhyt käyttöopas RIA45 digitaalinen prosessimittari, jossa ohjausyksikkö on paneelin asennettavassa kotelossa
EN FI 30/06/202221/11/201815/10/201530/01/201504/10/2012Kieli:
Suomi
Versio:
21/11/2018
Tiedoston koko:
1 MB
Tiedoston nimi:
KA00271RFI_1615.pdf
-
-
-
Ex Safety Instruction (XA)
RIA45, ORIA45
ATEX: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC
EN FI 27/06/202204/11/201615/04/201018/12/2008Kieli:
Englanti
Versio:
27/06/2022
Tiedoston koko:
481.4 KB
Tiedoston nimi:
XA00076REN_1422-00.pdf
-
-
-
Ex Safety Instruction (XA)
RIA45
CSA: Control Drawing AIS, ANI 120300112
Kieli:
Englanti
Versio:
08/06/2010
Tiedoston koko:
163.3 KB
Tiedoston nimi:
120300112.pdf
-
-
-
Ex Safety Instruction (XA)
RIA45
FM: Control Drawing AIS, ANI 120300111
Kieli:
Englanti
Versio:
03/06/2009
Tiedoston koko:
167.4 KB
Tiedoston nimi:
120300111.pdf
-
-
-
Certificates FM/CSA (ZD)
Control Drawing CSA AIS RIA45
Display with Control Functions RIA45 Installation Notes for hazardous locations
Kieli:
Englanti
Versio:
08/04/2010
Tiedoston koko:
278.3 KB
Tiedoston nimi:
120300112.pdf
-
-
-
Certificates FM/CSA (ZD)
Control Drawing FM approval AIS, ANI RIA45
Display with Control FunctionsRIA45 Installation Notes for hazardous locations
Kieli:
Englanti
Versio:
08/04/2010
Tiedoston koko:
257.9 KB
Tiedoston nimi:
120300111.pdf
-
-
-
Special Documentation (SD)
Functional Safety Manual RIA45
Functional safety manual for SIL2 certification of process meter RIA45
EN FI 07/02/201915/02/201708/04/201423/07/201215/06/2009Kieli:
Englanti
Versio:
07/02/2019
Tiedoston koko:
690.4 KB
Tiedoston nimi:
SD00014REN_1619.pdf
-
-
-
Manufacturer Information (MI)
RIA45 Panel meter with control unit Manufacturer Information regarding firmware and hardware update
RIA45 Panel meter with control unit Manufacturer Information regarding firmware and hardware update Electronic components have been changed, making a FW (xx.yy.zz) update at the zz position necessary. The error delay behavior of the analog input (4-20 mA NAMUR) was modified. The modification is not safety critical.
Kieli:
Englanti
Versio:
01/12/2020
Tiedoston koko:
111.9 KB
Tiedoston nimi:
MI01489K09EN_0121.pdf
-