iTHERM ModuLine TM131

Product picture of modular RTD and TC thermometer ModuLine TM131 with dual seal ©Endress+Hauser

Thermometer with second process barrier, so-called 'dual seal'

Product picture of modular RTD and TC thermometer ModuLine TM131 heavy duty ©Endress+Hauser

Stainless steel version with XP proof terminal head

Product picture of modular RTD and TC thermometer ModuLine TM131 QuickNeck ©Endress+Hauser

QuickNeck version for fast disassembly of the insert

Trend-setting, high modular and robust thermometer for a wide range of industrial applications

RTD or TC assembly complete with manufactured thermowell or to be used with existing thermowell. An optional head transmitter, with all common communication protocols - Bluetooth® technology inclusive, and special features like iTHERM QuickNeck, for tool-free easy recalibration, vibration-resistant and fast-response sensor and thermowell technology (iTHERM StrongSens, QuickSens) as well as hazardous area approvals makes the device ready to use with enhanced measurement accuracy and reliability.

Tämä tuote ei ole saatavilla tällä alueella.

  • Edut

    • Second process barrier with failure indication offering valuable health status information

    • iTHERM QuickSens: fastest response times 1.5 s for optimum process control

    • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety

    • ...

  • Käyttöalue

    • Universal range of application

    • Measuring range: –200 to +1100 °C (–328 to +2012 °F)

    • Pressure range up to 100 bar (1450 psi)

    • Degree of protection: up to IP 68

    • Vibration-resistant sensor elements up to 60g

    • Improved ease of maintenance (sensor replacement...

Ominaisuudet ja tiedot

Takaisin

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    universal range of application

    suitable for hazardous areas

    with neck or QuickNeck

    incl. thermowell / protection tube (metal) or to be installed into thermowell

    can be used with StrongSens, QuickSens insert

    for fast response times

  • Terminal head

    TA30A - comfort hinged cover E+H - Alu - low lid - with/without display

    TA20AB - small lid with screews - Alu

    TA30D - comfort high hinged cover E+H - Alu

    TA30EB - comfort screewed cover E+H - Alu - low lid - with/without display

    TA30R - low or high screewed cover - E+H - stainless steel - with/without display

    TA30H -explosion proof screewed cover - E+H - Alu or stainless steel - with/without display

    Dual-compartment fieldhousing - explosion proof - big backlit display - Alu or stainless steel

  • Thermowell / protection tube

    welded protection tube or to be used with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Thermowell:

    9x1,25 mm

    11x2 mm

    12x2,5 mm

    14x2 mm

    16x3,5

    1/4" SCH80

    1/2" SCH80

    1/2" SCH40

  • Max. immersion length on request

    up to 4.500,0 mm (177'')

  • Material protection tube/ thermowell

    316 (1.4401)

    316L (1.4404)

    316Ti (1.4571)

    Alloy 600 (2.4816)

    Alloy C276 (2.4819)

    Alloy 446 (1.4749)

    Alloy 321 (1.4541)

    Sheath PTFE

    Sheath Tantal

  • Process connection

    Thread:

    G3/8, G1/2", G3/4", G1"

    NPT1/2", NPT3/4", NPT 1"

    M18x1.5, M20x1.5, M27x2, M33x2

    R1/2", R3/4"

    Cap-nut:

    M20x1.5, G1/2", G3/4"

    Compression fitting:

    NPT1/2", G1/2", G1"

    Flansche:

    DN15 PN40 B1, C

    DN25 PN20, PN40, PN100 B1, B2, C

    DN40 PN40 B1

    DN50 PN40 B1

    ASME 1" 150 RF

    ASME 1" 300 RF

    ASME 1 1/2" 150 RF

    ASME 2" 150 RF

    ASME 2" 300 RF

  • Tip shape

    straight

    reduced

    tapered

    optimized for quick response times

  • Surface roughness Ra

    < 1.6 μm (63.00 μin)

  • Operating temperature range

    PT100 TF StrongSens:

    -50 °C ...500 °C

    (-58 °F ...932 °F)

    PT100 QuickSensTF:

    -50 °C …200 °C

    (-58 °F …392 °F)

    PT100 WW:

    -200 °C ...600 °C

    (-328 °F ...1.112 °F)

    PT100 TF:

    -50 °C ...400 °C

    (-58 °F ...752 °F)

    Thermoelement:

    Typ K up to 1.100 °C (2.012 °F)

    Typ J up to 800 °C (1.472 °F)

    Typ N up to 1.100 °C (2.012 °F)

  • Max. process pressure (static)

    depending on the configuration up to 100 bar

  • Accuracy

    Class AA acc. to IEC 60751

    Class A acc. to IEC 60751

    Class B acc. to IEC 60751

    Class special or standard acc. to ASTM E230

    Class 1 or 2 acc. to IEC 60584-2

  • Response time

    fastest response time with thermowell t90 starting at below 10 s

    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX

    ATEX IECEx

    NEPSI

    IECEx

    EAC Ex

    CSA C/US

  • Certification

    SIL, MID, DNV/GL

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely