Omnigrad S TAF12T
High temperature TC thermometer

Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser
Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser
Omnigrad S TAF12T
High temperature TC thermometer ©Endress+Hauser

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • Edut

    • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

    • Long term stable measurement due to sensor protection with non-porous materials

    • Flexible product selection by modular design

    • Optimized life cycle costs by...

  • Käyttöalue

    • The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.

    • ...

Ominaisuudet ja tiedot

Takaisin

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Thermocouple

  • Characteristic / Application

    metric style

    modular temperature assembly

    high temperature (furnace)

    ncl. triple ceramic thermowell

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20D - aluminium - hinged cover high

    TA30A - E+H, aluminium - cover low - w/o. display

    TA30D - E+H, aluminium - cover high

    DIN A - aluminum

  • Thermowell / protection tube

    ceramic protection tube and 2x inner tube

  • Insert / probe

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    24,0 mm (0,94")

    26,0 mm (1,02")

  • Max. immersion length on request

    up to 3.500,00 mm (137,80'')

  • Material protection tube/ thermowell

    Ceramic (C530/C610/C799)

  • Process connection

    compression fitting:

    G11/2"

  • Tip shape

    straight

  • Operating temperature range

    Type S:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Type R:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Type B:

    600 C ...1.700 C

    (1.112 F ...3.092 F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely