Ultrasonic measurement
Time-of-Flight
Prosonic FMU42

Prosonic FMU42 ©Endress+Hauser

Time-of-Flight measuring principle

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m

The Prosonic FMU42 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Pikavalinta

Tee valinta ehdotetuista vaihtoehdoista
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

tai

Yksilöllinen konfiguraattori

Jatka valintaa kaikista mahdollisista vaihtoehdoista
  • Edut

    • Reliable non-contact measurement

    • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

    • Envelope curves on the on-site display for simple diagnosis

    • Hermetically sealed and potted sensor

    • ...

  • Käyttöalue

    Two-wire or four wire instrument for continuous non-contact level and flow measurement.

    • Process connection: Flange

    • Temperature: -40 to +80°C (-40 to +176°F)

    • Pressure: +0.7 to +2.5bar (+10 to +36psi)

    • Maximum measuring distance: Liquids 10m (33ft), Solids...

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3", JIS 10K 80
    DN100,ASME 4", JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    5 m (16 ft)

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Mittausperiaate

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3", JIS 10K 80
    DN100,ASME 4", JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Application

  • Max. measurement distance

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely