Radiometric
Level and density
Source Container FQG66

Source Container FQG66 ©Endress+Hauser
Source Container FQG66 ©Endress+Hauser
Source Container FQG66 ©Endress+Hauser
Source Container FQG66 ©Endress+Hauser

Radiometric measuring principle

Radiation source container with sliding source support rod for manual or pneumatic on/off switching

The FQG66 source container is designed to hold the radioactive source with highest activities during radiometric point level detection, continuous level and density measurement. The radiation is emitted almost unattenuated in one direction only, and is damped in all other directions. This guarantees highest safety for the personnel and a reliable measurement.

  • Edut

    • High safety level thanks to highest safety classification for the source supplied
      (DIN 25426/ISO 2919, typically classification C66646) and simple and easy source replacement

    • Extremely high shielding ensures that no control areas are generally required...

  • Käyttöalue

    Encloses the radioactive source used for radiometric point level detection, level and density measurement. Operating with very high sensitivity rod scintillation detectors, provide lowest possible radiation loads in the surrounding.

    • Used if the...

Yksityiskohtaiset tiedot

  • Mittausperiaate

    Radiometric Limit

  • Characteristic / Application

    Source container

    Emission angle: 5 degrees

    Approximately 435 kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -55 °C ... +100 °C
    (-67 °F ...+212 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

  • Mittausperiaate

    Radiometric

  • Characteristic / Application

    Source container

    Emission angle: 40 / 20 degrees

    435kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -55 °C...+100 °C
    (-67 °F...+212 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Mittausperiaate

    Radiometric Limit

  • Characteristic / Application

    Source container

    Emission angle: 5 degrees
    435kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -55 °C...+100 °C

    (-67 °F...+212 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

  • Mittausperiaate

    Radiometric Density

  • Characteristic / Application

    Source container

    Emission angle: 5/ 20 / 40 degrees

    435kg

  • Ambient temperature

    -55 °C...+100 °C

    (-67 °F...+212 °F)

  • Process temperature

    Any

  • Process pressure absolute

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator

  • Mittausperiaate

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    435kg

  • Specialities

    Sliding source support rod for manual or pneumatic on/ off switching

  • Ambient temperature

    -55 °C...+100 °C
    (-67 °F...+212 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

Asiakirjat / käsikirjat / ohjelmisto

Tarvikkeet / varaosat

Nro
Tilauskoodi
Erittely