This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Thermocouple
-
Characteristic / Application
US style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
1/4" SCH80
1/2" SCH80
1/2" SCH40
3/4" SCH80
3/4" SCH40 -
Max. immersion length on request
up to 10.000,00 mm (393,70'')
-
Material protection tube/ thermowell
1.4401 (316)
1.4749 (~446) -
Optional coating
Not defined
-
Process connection
male thread:
NPT1/2"
NPT3/4"
NPT1"
compression fitting:
flange:
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
ASME 1" 600 RF (B16.5)
ASME 1,5" 150 RF (B16.5)
ASME 1,5" 300 RF (B16.5)
ASME 1,5" 600 RF (B16.5)
ASME 2" 300 RF (B16.5)
ASME 2" 600 RF (B16.5) -
Tip shape
straight
reduced -
Surface roughness Ra
1,6 μm (63,0 μin.)
-
Operating temperature range
Type K:
-40 °C ... 1.100 °C
(-40 °F ...2.012 °F)
Type J:
-200 °C ...750 °C
(-328 °F ...1.382 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof -
Certification
Gost Metrology
SIL (transmitter only)