Specs at a glance
-
Accuracy
+/- 2mm + 0.17% of measured distance
Field of application
Prosonic FMU95 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids.
Continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk materials with up to 5 or 10 ultrasonic sensors.
Measuring range up to 45m (148ft) (depending on sensor and material measured)
Calculation of average values or sums
Benefits
Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
Envelope curves on the display for quick and simple diagnosis
Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
Time-of-Flight correction via integrated or external temperature sensors
Linearization (up to 32 points, freely configurable)
System integration via PROFIBUS DP with up to 20 measured values
Automatic detection of the sensors FDU9x
Videos
-
Time-of-Flight measuring principle
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version
-
Specialities
Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors -
Supply / Communication
90 ... 253 VAC
10.5 ... 32 VDC
Profibus DP -
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C ... 60 °C
(-40 °F ... 140 °F) -
Communication
Profibus DP
-
Certificates / Approvals
ATEX, CSA
-
Options
Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
-
Components
Sensors FDU9x
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version
-
Specialities
Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors -
Supply / Communication
90 ... 253 VAC
10.5 ... 32 VDC
Profibus DP -
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C ... 60 °C
(-40 °F ... 140 °F) -
Communication
Profibus DP
-
Certificates / Approvals
ATEX, CSA
-
Options
Illuminated display, 6 line graphic display with country specific menu guidance
-
Components
Sensors FDU9x
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories